N7201A617E00_0317 - 第397页

NPM-W 2 EJM7DE-MB-13 M-00 13-8-2 -4 Confirm the display value (The value is displayed, and the lamp flashes) (The input value 1 is set) (Teaching is complete and then the lamp changes from flas hing to illumination) Conf…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
Place-
ment
load
How to use placement load
measurement jig
(option) 2
1
2
3
13-8-2-3
Maintenance
13-8-2
Calibration method 1
You do not need to set the value because it is already initialized before shipment.
Please calibrate the jig or the load cell after you replace it. Also, it is recommended that you calibrate it
every year.
Turn ON the power
Hold down
for at least three seconds
Confirm the input range
If the screen display differs
Choose it with
4
5
Confirm the power-supply
frequency
6
(The input range is set)
(The power-supply frequency is set)
(The screen display flashes)
If the screen display differs
(The screen display flashes)
Choose it with
3
5
34
6
2
5
NPM-W2 EJM7DE-MB-13M-00
13-8-2-4
Confirm the display value
(The value is displayed, and the lamp
flashes)
(The input value 1 is set)
(Teaching is complete and then the lamp
changes from flashing to illumination)
Confirm that the display value
becomes stable
(The display value 1 is set)
If the screen display differs
(The display flashes)
Choose it with
8
9810
9
11
1112
10
11
7
8
9
12
Put a 100g weight on the load
cell
Calibration
NPM-W2 EJM7DE-MB-13M-00
Place-
ment
load
How to use placement load
measurement jig
(option) 3
13-8-2-5
Maintenance
13-8-2
(The value is displayed, and the lamp
flashes)
(Teaching is complete and then the lamp
changes from flashing to illumination)
Confirm that the display value
becomes stable
(The input value 2 is set)
Confirm the display value
(The display value 2 is set)
If the screen display differs
(The display flashes)
Choose it with
14
151416
15
17
1718
13
14
15
16
17
18
Calibration method 2
Put a 1kg weight on the load cell