N7201A617E00_0317 - 第400页

NPM-W 2 EJM7DE-MB-13 M-00 Multi-r ecognition camer a 1 Explains the multi-recognition camera operating proc ed ure, taking for an example, the 12-nozzle hea d; however, the same pro cedure can als o be applied to the lig…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
13-8-2-6
19
19
20
21
192021
Confirm the decimal point position
(The decimal point position is set)
To change
(The screen display flashes)
Hold down
for at least a second
(Returns to the operation level)
Choose it with
Calibration
NPM-W2 EJM7DE-MB-13M-00
Multi-recognition
camera 1
Explains the multi-recognition camera operating procedure, taking for an example, the 12-nozzle head;
however, the same procedure can also be applied to the light weight16-, 8-, and 3-nozzle heads.
Remove the feeder, if any, from the table you are going to calibrate beforehand.
Choose a head
+
13-9-1
Choose the head you want to calibrate.
Maintenance
13-9
12
2
1
(The head moves to the work position)
Open the safety cover
Install the multi-recognition
camera jig
Nozzles used
Head
type
Nozzle
position
16 No. 5
12 No. 4
8No. 3
3No. 2
Servo switch OFF
3
4
5
Close the safety cover
Servo switch ON
6
7
Multi-recognition camera jig
For light weight16-, 12-,
8-nozzle head
For 3-nozzle head
NPM-W2 EJM7DE-MB-13M-00
13-9-2
Calibration
+
Confirm the message
To cancel
(The screen remains as it is in )
8
1
+
9
(The head moves to the work position)
9
Confirm that it has been
successfully completed
8
Prepare to attach the jig
Servo switch OFF
Open the safety cover
Head
type
Nozzle position
Before replace After replace
16 No. 5 No. 12
12 No. 4 No. 9
8 No. 3 No. 6
3 No. 2 No. 1
10
11
12
13
Replace the multi-recognition
camera jig
Nozzles that you confirm