N7201A617E00_0317 - 第431页

NPM-W 2 EJM7DE-MB-13 M-00 5 5 Confirm the message + (The head moves to the retraction position.) Open the safety cover User master plate Close the safety cover 13-14 -2 Calibration plate Multi-recognition c amera Calibra…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
White balance 1
(2D inspection head)
13-14-1
Maintenance
13-14
1
4
1
2
Choose a table
+
4
3
Enter the target value
A
Solder inspection (after printing)
B
Component inspection (before placement
and after placement)
Label
3
Make sure that the serial number
written on the case of the user master
plate matches.
Type the target values (R, G, B)
written in the case label according to
inspection.
2
A
B
This is calibration for the inspection head.
The inspection head uses the color and brightness information of images taken with the color camera to
asses an inspection.
Adjust White balance is the function that calibrates and restores the camera to normal state so that the
inspection head can properly perform an inspection.
To adjust the white balance, a calibration plate and a user master board are used. The machine employs the
calibration plate to calibrate the color and brightness of the camera. In addition, because the color and
brightness of the calibration plate itself can change due to staining on the surface, aging, etc., you can also
use the user master board for calibration.
Therefore, whenever adjusting the white balance, you should also obtain the target value for the calibration
plate. This is used for the inspection head only.
Target value for SPI
Target value for AOI
NPM-W2 EJM7DE-MB-13M-00
5
5
Confirm the message
+
(The head moves to the retraction
position.)
Open the safety cover
User master plate
Close the safety cover
13-14-2
Calibration plateMulti-recognition camera
Calibration jig
8
7
9
11
10
6
Confirm the message and
prepare for installing the user
master plate
Place the user master plate to
the right side of the calibration
jig
CAUTION
Do not climb on equipment, peripheral devices and moving parts
Calibration jig, Multi-recognition camera
Do not touch the user master plate and calibration plate directly with your bare hands. Doing so they may
get dirt.
ATTENTION
Servo switch ON
Servo switch OFF
Calibration
Do not touch the surface of the user
master plate with your bare hands.
Before setting up the user master
plate, move it to the center of the
calibration jig.
NPM-W2 EJM7DE-MB-13M-00
13-14-3
Maintenance
13-14
12
12
Confirm the message
+
13
13
+
(The head moves to the retraction
position.)
14
Open the safety cover
15
Remove the user master board
from the left front of the
calibration jig
16
18
17
Close the safety cover
19
19
Confirm the message
White balance 2
(2D inspection head)
Servo switch ON
Servo switch OFF
The white balance adjustment
processing is performed.
Upon completion of the white
balance adjustment,
Confirm the message