NPM-W 2 EJM7DE-MB-13M-00 13-15 -3 9 9 10 Confirm the message 10 Calibration (The d ata obtained by ca libration is saved)

NPM-W2 EJM7DE-MB-13M-00
13-15-2
6
6
7
7
8
8
(The screen for the measured camera
offsets (offsets of the four standard
posts in reference to the mark 1) is
displayed.
Camera offset 2
(2D inspection head)
Maintenance
13-15

NPM-W2 EJM7DE-MB-13M-00
13-15-3
9
9
10
Confirm the message
10
Calibration
(The data obtained by calibration is
saved)

NPM-W2 EJM7DE-MB-13M-00
Image quality correction
(2D inspection head)
13-16-1
Maintenance
13-16
The inspection head measures solder and component positions based on an image captured by the color
camera. This function corrects distortion of the camera image in order to make a precise measurement.
The distortion correction plate is used for image correction. The machine corrects the camera image based
on the measurement result using this jig that its accuracy is guaranteed.
1
2
5
4
3
Check a calibration jig and a
distortion correction plate
Close the safety cover
Open the safety cover
Servo switch ON
Servo switch OFF
Distortion correction plate
Calibration jig
●When calibration is carried out, make
sure that the calibration jig is securely
tightened and the distortion correction
plate is not dirty. If it is dirty, clean it
with a blower brush.