N7201A617E00_0317 - 第438页

NPM-W 2 EJM7DE-MB-13M-00 Ima ge quality cor r ection (2D inspection head) 13-16 -1 Maintenance 13-16 The inspection hea d measures solder and compone nt positions based on an image capture d by the color camera. This fun…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
13-15-3
9
9
10
Confirm the message
10
Calibration
(The data obtained by calibration is
saved)
NPM-W2 EJM7DE-MB-13M-00
Image quality correction
(2D inspection head)
13-16-1
Maintenance
13-16
The inspection head measures solder and component positions based on an image captured by the color
camera. This function corrects distortion of the camera image in order to make a precise measurement.
The distortion correction plate is used for image correction. The machine corrects the camera image based
on the measurement result using this jig that its accuracy is guaranteed.
1
2
5
4
3
Check a calibration jig and a
distortion correction plate
Close the safety cover
Open the safety cover
Servo switch ON
Servo switch OFF
Distortion correction plate
Calibration jig
When calibration is carried out, make
sure that the calibration jig is securely
tightened and the distortion correction
plate is not dirty. If it is dirty, clean it
with a blower brush.
NPM-W2 EJM7DE-MB-13M-00
13-16-2
6
7
8
Choose a table
+
6
8
(The head operates to measure the
distortion)
Confirm that it has been
successfully completed
Calibration
7
If an error occurs, check if the
distortion correction plate is dirty. If it
is dirty, clean it with a blower brush
and then try making measurement
again.
If you fail to correct the error with the