N7201A617E00_0317 - 第460页

NPM-W 2 EJM7DE-MB-13 M-00 Maintenance 13-21-1 13-21-1 -1 Ov er view 1 (placement head / dispensing head) Accuracy verifica- tion Accuracy verification ■ MCDA T A type MCDATA (productio n progra m) is exclus ively used fo…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
13-20-4
Calibration
17
19
20
22
21
23
23
18
To cancel
(The screen remains as it is
in )
11
Confirm the message
+
Open the safety cover
Remove nozzles
Close the safety cover
Prepare to remove nozzles
Servo switch ON
Servo switch OFF
NPM-W2 EJM7DE-MB-13M-00
Maintenance
13-21-1
13-21-1-1
Overview 1
(placement head / dispensing head)
Accuracy
verifica-
tion
Accuracy verification
MCDATA type
MCDATA (production program) is exclusively used for accuracy verifications.
There are the following two types of MCDATA used for placement accuracy verifications.
Offset Refection MCDATA
*The one with “Ost” included in its
data name
The front and rear heads execute placement independently from each
other, and the placement locations are measured. This is used to
reflect the each-position-angle offsets, obtained from measurement
results, separately as the front or rear head use.
Accuracy Verification MCDATA
*The one with “Ins” included in its
data name
The front and rear heads execute alternate placement that is an
operation close to normal placement, and this is used in measuring the
placement locations.
MCDATA filename
W2 - L16 -L16 - F F _ 05JIG - Ost ***
Reflection of verification data
Make sure not to reflect the each-position-angle offsets, obtained after measurement, in “Accuracy verification
MCDATA” because the MCDATA is used for verification purpose.
When using MCDATA for component placement, the following message appears before the start of production.
Select [Yes] / [No] according to the type of the data you use.
When accuracy is verified using ‘Offset Refection
MCDATA’ (-Ost)
When accuracy is verified using ‘Accuracy Verification
MCDATA’ (-Ins)
+
+
Machine name W2 (NPM-W2)
Head
configuration
L16: light weight 16-nozzle / M12: 12-nozzle / M08: 8-nozzle / M03: 3-nozzle / NON:
without heads / I18: inspection head 18μm / I09: inspection head 9μm / D02:
dispensing head / ALL: This is used only when inspection head is verified, and the
type of the diagonal head is not considered
Supply unit
configuration
F: feeder / TT: twin tray feeder / FT: 13-slot feeder + Tray feeder / N: when head
configuration is either no head or dispensing head
Component
05JIG: 1005 jig component / 02R: 0402R / 015R: 03015R / BGA: BGA jig
component
Mode
Ost: for offset reflection use / Ins: for accuracy verification use / InsH: 0.025 mm-
ready accuracy verification use
Available nozzle
①②
Explains considerations for accuracy verification.
About accuracy verification of the machine with a combination of the placement head and the inspection
head, see P.13-21-1
-7.
NPM-W2 EJM7DE-MB-13M-00
13-21-1-2
Calibration
Order of verification (placement head)
Light
weight 16-
nozzle head
12-nozzle
head
8-nozzle
head
3-nozzle
head
Chip(1005JIG) offset reflection
①①①
*2)
Chip(1005JIG) accuracy verification
②②②
*2)
Chip(1005JIG) accuracy verification (± 0.025
mm support)
*1)
――
Micro(0402R) offset reflection
③③③
Micro(0402R) accuracy verification
④④④
Micro(03015R) accuracy verification
――
General-purpose(JIG_BGA) offset reflection ――
⑤①
General-purpose(JIG_BGA) accuracy
verification
――
⑥②
1) If ±0.025 mm support is optionally selected, only chip accuracy verification (± 0.025 mm support) is
performed and chip accuracy verification is not performed.
2) Perform it when using a 3-nozzle head to mount a component with 12 mm or less.
Target value for accuracy verification
NPM-W2 is capable of providing support for high production mode (placement accuracy 40 μm) and high
accuracy mode (30 μm). Use high accuracy mode in accuracy verifications.
Placement accuracy Target value list
Target value
Micro (03015R) accuracy verification
±0.03 mm
*1)
Micro (0402R) accuracy verification
±0.03 mm
*2)
Chip(1005JIG) accuracy verification
±0.03 mm
General-purpose(JIG_BGA) accuracy
verification
±0.03 mm
1) Measures when support for 03015 placement (option)
is provided
2) ±0.025 mm when support for ±0.025 mm (option) is
provided
How to set
([Operating Procedure] P.6-1-20 ‘Soft switch
setting’)
Order of accuracy verification varies according to head specifications. Perform in the order below according to
the head to be verified.
Inspection accuracy Target value list
Target value
9 μm
±0.010 mm
18 μm
±0.020 mm
Dispensing accuracy Target value list
Target value
Dot dispensing accuracy verification
±0.075 mm