N7201A617E00_0317 - 第475页

NPM-W 2 EJM7DE-MB-13M-00 13-21-2 -6 8 9 10 11 8 9 Choose a nozzle to display (Offset per nozzle is displayed) Choose a table to display 10 Choose a placed part ● Displayed based on the part type. B 6 7 A 6 Choose a table…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
1
Upon completion of placement,
Checking and reflection of placement (checking placement results)
Accuracy
verifica-
tion
2
(Automatic run ends)
+
2
13-21-2-5
3
4
5
3
4
5
Switch it with
When you do not end
Maintenance
13-21-2
Detailed process 3
(placement head)
( P.13-21-1-2 Target value for
accuracy verification’)
NPM-W2 EJM7DE-MB-13M-00
13-21-2-6
8 910
11
8
9
Choose a nozzle to display
(Offset per nozzle is displayed)
Choose a table to display
10
Choose a placed part
Displayed based on the part type.
B
6
7
A
6
Choose a table
(Displays the accuracy of the front and the
rear individually or the total accuracy)
Cpk prescribed values per component
( P.9-1-1 ‘Basic performance’ in
[Operating procedure] )
A
Cpk
If the measurement result Cpk is
lower than the prescribed value,
Angle Offset is reflected.
7
To reflect mount offset
Offset per nozzle is displayed
B
X[mm], Y[mm], θ[°]
To reflect the verification data
11
For
For other than
12
13
To
To
Calibration
Confirm the message
To use accuracy verification MCDATA:
( P.13-21-1
-1 Reflection of verification
data’)
NPM-W2 EJM7DE-MB-13M-00
13-21-2-7
Checking the placement result (reflection of verification data, offset registration)
Accuracy
verifica-
tion
Detailed process 4
(placement head)
Maintenance
13-21-2
12
(The data is reflected and machine
parameters are updated)
Regardless of the table
selected for data display
All heads
Nozzle offset
are updated.
It can be replaced so that you can check the placement accuracy.
In doing so, please do [Checking the placement result] on P.13-21-2
-8.
NOTE
12
Confirm the message
For a part up to the size of the 0402
chip
For a part larger in size than the
0402 chip
Confirm the message
13
When you do not save the data
13