NPM-W 2 EJM7DE-MB-13M-00 13-21-2 -7 Checking the placement result (reflection of verification data, offset registration) Accuracy verifica- tion Detailed pr ocess 4 (placement head) Maintenance 13-21-2 12 (The data is re…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
13-21-2-6
8 910
11
8
9
Choose a nozzle to display
(Offset per nozzle is displayed)
Choose a table to display
10
Choose a placed part
Displayed based on the part type.
B
6
7
A
6
Choose a table
(Displays the accuracy of the front and the
rear individually or the total accuracy)
Cpk prescribed values per component
( P.9-1-1 ‘Basic performance’ in
[Operating procedure] )
A
Cpk
If the measurement result Cpk is
lower than the prescribed value,
Angle Offset is reflected.
7
To reflect mount offset
Offset per nozzle is displayed
B
X[mm], Y[mm], θ[°]
To reflect the verification data
11
For
For other than
12
13
To
To
Calibration
Confirm the message
To use accuracy verification MCDATA:
( P.13-21-1
-1 Reflection of verification
data’)
NPM-W2 EJM7DE-MB-13M-00
13-21-2-7
Checking the placement result (reflection of verification data, offset registration)
Accuracy
verifica-
tion
Detailed process 4
(placement head)
Maintenance
13-21-2
12
(The data is reflected and machine
parameters are updated)
Regardless of the table
selected for data display
All heads
Nozzle offset
are updated.
It can be replaced so that you can check the placement accuracy.
In doing so, please do [Checking the placement result] on P.13-21-2
-8.
NOTE
12
Confirm the message
For a part up to the size of the 0402
chip
For a part larger in size than the
0402 chip
Confirm the message
13
When you do not save the data
13
NPM-W2 EJM7DE-MB-13M-00
13-21-2-8
Checking of placement result
Cause Troubleshooting
The target components are deteriorated
Check for any flaws or foreign bodies on the
surface of JIG_BGA.
The correct jig parts are not used. Check the jig parts.
Actual parts 1005C are used. Check the jig parts.
The head shaft is damaged Check for unsmooth sliding of the shaft.
The illumination of the multi-recognition
camera is wrong.
Execute the lamp-value illumination calibration.
Calibration
If you perform above measures, but the accuracy verification result is not improved or you find any trouble
on the head shaft, please contact us.
Verifies the results registered as offsets in “Checking and reflection of placement.” The procedure is the
same as the one used in “Checking and reflection of placement.”
Though not necessarily required, this procedure will be used as a guideline for measuring the level of
accuracy of the machine.
As for MCDATA (production program), use accuracy verification MCDATA.
( P.13-21-1
-1 MCDATA type’)
Accuracy verification MCDATA is intended for accuracy verification use, so refrain from reflecting in it the
each-position-angle offsets obtained from measurement results.
( P.13-21-1
-1 Reflection of verification data’)
The following causes are cited as possible causes when no improvements are seen in accuracy verification
results.