N7201A617E00_0317 - 第482页

NPM-W 2 EJM7DE-MB-13 M-00 Checking and reflection of measurement (measurement) ENABLING 3 2 1 (First layer) (Second laye r) Do not press the STOP button while a ccuracy verification is carried out. You cannot re start op…

100%1 / 572
NPM-W2 EJM7DE-MB-13M-00
Production preparation 3 (生産動作の設定)
Production preparation 3 (Setting of production)
1
Turn OFF all items except
[Inspection] and [PCB recog.]
13-21-2-12
1
Calibration
NPM-W2 EJM7DE-MB-13M-00
Checking and reflection of measurement (measurement)
ENABLING
321
(First layer)
(Second layer)
Do not press the STOP button while accuracy verification is carried out.
You cannot restart operation in the middle of accuracy verification.
NOTICE
6
Measure the
plane correction
jig
Measure the jig in
automatic operation. After
the measurement ends
and the its operation stops,
end the automatic
operation
4
Confirm the
message
ENABLING
5
To use accuracy verification
MCDATA:
( P.13-21-1
-1 Reflection
of verification data’)
13-21-2-13
Accuracy
verifica-
tion
Detailed process 7
(inspection head)
Maintenance
13-21-2
NPM-W2 EJM7DE-MB-13M-00
Checking and reflection of measurement (checking of the measurement result)
1
2
3
2D inspection head
A type:
Resolution: 18 μm ± 0.020 mm
B type:
Resolution: 9 μm ± 0.010 mm
1
2
3
4
5
A
4
Choose a table of the
inspection head
Cpk prescribed value per component
( P.9-1-1 ‘Basic performance’ in [Operating procedure] )
A
Cpk
5
Switch it with
13-21-2-14
Calibration
When offset reflection MCDATA is
used, always reflect the inspection
camera offset.