N7201A617E00_0317 - 第499页
NPM-W 2 EJM7DE-MB-14M-00 14-3 -4 ● Store the detached br ackets. ● Bracket: 6 locations 3 Detach fixing brackets (red color) X-axis fixing bracket (2 pcs) Y -axis fixing bracket (4 pcs) A B Common To 4 Installation A A B…

NPM-W2 EJM7DE-MB-14M-00
14-3-3
1
Install
Temporarily locate the machine along the
baseline drawn on the floor and adjust the
installation position.
●Adjust the height and facing of the machine
to guarantee a smooth PCB transfer
between the machine and adjacent
equipment.
●Keep a 1 to 5 mm space between the
machine and adjacent equipment.
●If running a vent under the machine, keep a
40 mm or more space between the machine
and the vent.
(The figure on the right shows the minimum
space and is measured in millimeters (mm))
Twin tray feeder
(Option)
Feeder cart
2
Check the working area
1 190
2 000
Working area
Front side
To
(P.14-3-4)
3
Front side: Feeder cart / Rear side: Twin tray feeder
Front side
Rear side
Working area
1 080
1 830
Maintenance
14-3
Installation 2
NOTICE
Coverendface
Coverendface
●Regarding installation, follow the instructions of
a specialist.
●Regarding relocation, contact us, please.
Cover end
face
Cover end
face
1 080 1 190
4 602
2 332

NPM-W2 EJM7DE-MB-14M-00
14-3-4
●Store the detached brackets.
●Bracket: 6 locations
3 Detach fixing brackets (red color)
X-axis fixing bracket (2 pcs)
Y-axis fixing bracket (4 pcs)
A
B
Common
To
4
Installation
A
A
B
B
B
B
A

NPM-W2 EJM7DE-MB-14M-00
14-3-5
Installation 3
Common
4
Level the machine
Place level gauges as shown in the right figure.
●Level: 4 locations
Level the machine with the adjustment bolts.
●The bubble should stay centered or within 1
division. (0.02 mm/m)
●4 adjustment bolts
Secure the adjustment bolts with the lock nuts.
You are recommended to check the level every six months after installation.
NOTICE
Level gauge installation sites
Adjustment bolts
PCB transfer
height
900 to 920 mm
1
2
3
Front side
Lock nut
Adjustment
bolt
■About PCB transfer height
●The standard PCB transfer height of NPM-W2 is from 900 to 920 mm.
●If the PCB transfer heights of all your production-line NPM-W2s cannot be 900 to 920 mm, please
consult our sales representative or customer service in advance.
●Depending on your plant floor conditions, the PCB transfer heights of your production-line machines
can vary as shown in the figure below, in which feeder carts may not be connected normally to
machines #2 and #15.
900
mm
885
mm
920
mm
Floor
PCB
transfer
height
#1 #2 #7 #8 #15
940
mm
NG NGOK OK OK
Maintenance
14-3