N7201A617E00_0317 - 第528页

NPM-W 2 EJM7DE-MB-14M-0 0 14-10 -1 Attac hing and detac hing the saf ety co v er (option) Maintenance 14-10 How to attach Attach the safety cover (option) ● Attach the safety c over to th e main body while ensur ing the …

100%1 / 572
NPM-W2 EJM7DE-MB-14M-00
14-9-7
You can arrange positions of the inspection head and conveyor flexibly according to your purpose.
To be shorter the line length
PCBs resulting in NG by the solder inspection (SPI) and the component inspection (AOI) stop all
together on the inspection ejection conveyor at the end of line. Regarding placement points or patterns
judged as NG by the solder inspection (SPI), placement and component inspection (AOI) are also
automatically skipped.
To inspect foreign matters against two types of components (reel type and tray type)
In foreign matters inspection, whether foreign matters are exists under the specified component or not is
inspected. If any foreign matter is found, the specified component is not placed. Therefore, this
component must be moved to the diagonal head of inspection or the downstream process. If both the
reel type and tray type are mixed together, arrange the machine as shown below. However a
component placed on the downstream process is not inspected even after placed.
Installation
Solder inspection
(SPI)
Component
inspection
(AOI)
Component
inspection
(AOI)
Inspection
ejection
conveyor
Inspection
ejection
conveyor
NPM-W2 EJM7DE-MB-14M-00
14-10-1
Attaching and detaching
the safety cover
(option)
Maintenance
14-10
How to attach
Attach the safety cover (option)
Attach the safety cover to the main body while ensuring the main-body drawer connector and the
connector on the safety cover reverse side are engaged with each other.
Tighten four bolts
on the safety
cover front side
Bolt
1
2
3
4
5
6
ON
OFF
Front side
Rear side
This safety cover covers the machine opening section when the feeder cart or tray feeder is not necessary to
ensure your safety.
How to attach and detach the safety cover is described as an example of working from the front side.
Detach the feeder cart (option) and the tray feeder before work.
(For how to detach the feeder cartP.3-2, and for how to detach the tray feederP.14-8)
The safety cover for NPM-W cannot be used.
The safety cover cannot attach to /detach from the machine with independent changeover support unit installed.
(Dispensing head specification,
2D inspection head specification,
Non-head specification)
(Dispensing head specification,
Non-head specification)
NPM-W2 EJM7DE-MB-14M-00
14-10-2
How to detach
Loosen four bolts
on the safety
cover front side
Remove the
safety cover
(option)
Bolt
Installation
OFF
ON
1
2
4
5
3
6