NPM-W2 EJM7DE-MB-15M-00 16-2 -2 Accidental release measures Personal pr ecautions When removing this product, be sure to wear suitable protective g ear. In ca se of a large scale release, Any person other than response p…

NPM-W2 EJM7DE-MB-15M-00
Maintenance
16-2
Safety data sheet (SDS) 1
(LCG100)
16-2-1
First aid measures
Inhalation Remove to fresh air. Place a blanket, etc. over the person to keep them warm and
resting. Get medical attention as necessary.
Skin contact Remove the contaminated clothing and shoes immediately. Rinse skin with plenty of
water or hot water and soap. If suffering from contact with a heated product rinse
skin and take aid for a burn. Get medical attention as necessary if symptoms such
as a rash and pain occur.
Eye contact Wash eyes with plenty of water and get medical attention immediately. Open your
eyelids wide with fingers and wash the entire eyeball and lid with plenty of water.
When wearing contact lenses, remove them and continue washing your eyes unless
the lenses stick on your eyes.
Ingestion Do NOT induce vomiting. Get medical attention immediately. Inducing vomiting
increases risk of aspirating oil to lung. If the inside of the mouth is contaminated,
rinse it with plenty of water.
Brief information on
the most important
signs and symptoms
IF ingested, symptoms such as diarrhea and vomiting may occur.
In case of eye contact, inflammation may appear.
In case of skin contact, inflammation may appear.
If inhaling mist or vapor, symptoms such as nausea and vomiting may occur.
Extinguishing agent Dry chemical powder, foam, carbon dioxide, fog, etc. are effective.
Extinguishing agents
that cannot be used
Fog water can be used to cool down. However water jet must not be used to
extinguish fire. Otherwise fire may spread and pose a danger.
Extinguishing method
specified
Stand on the windward side as much as possible to extinguish fire. Any person other
than response personnel must not enter the fire area. Remove ignition source from
the origin of fire and use suitable agent. In case of an early stage fire, use dry
chemical powder and carbon-dioxide extinguisher. For a large-scale fire, it is
effective to use foam agent to block out air currents. Water may pose danger of
expanding the fire.
Protection of fire-
fighters
When extinguishing fire, be sure to stand on the windward side and wear protective
gear. Since there is a possibility that toxic gas (carbon monoxide, etc.) is generated
by combustion and high temperature, use a respirator.
This [Safety data sheet (SDS)] is described based on information provided by the oil manufacturer.
Oil name: LCG100
Manufactured by: Panasonic Factory Solutions Co., Ltd
Fire fighting measures

NPM-W2 EJM7DE-MB-15M-00
16-2-2
Accidental release measures
Personal precautions When removing this product, be sure to wear suitable protective gear. In case of a
large scale release,
Any person other than response personnel will be prevented from being in the
release area by taking measures such as putting rope around the area.
Environmental
precautions
Great care must be taken to ensure that this product is not released into rivers or
sewerage, etc. so it does not affect the environment.
Removal method Remove release source and stop releasing. In case of a small scale release,
remove this product with scoops and shovels. Or absorb it with soil, lint free cloth,
etc., put it into empty containers, and wipe this product away thoroughly with a lint
free cloth, etc. In case of a large scale release, block released grease with soil, lead
it into a safe place and put it into empty cases as much as possible so as not to let it
release into rivers or sewerage. If released onto the sea, put oil fence on the sea to
prevent spread and absorb it with absorption mat, etc. Agent, if used, must comply
with the technical standards stipulated by Ministry for Land, Infrastructure, Transport
and Tourism.
Handling and storage
■Handling
Tech-
nical
mea-
sures
Human
exposure
prevention
When handling, be sure to wear suitable protective gear and avoid direct contact.
When removing this product from the container, use suitable tools. Do not put this
product into your mouth or ingest it.
Fire and
explosion
prevention
Be careful of flame. Avoid contact with flames, sparks, and hot products. Take
static-electricity measures. Wear non-conductive clothes and shoes. When repairing
or modifying a machine with this product still on, put the machine in a safe place and
remove oil thoroughly beforehand. Use flameproof electric devices (with safety
structure).
Other
cautions
Handle oil at room temperature. Be careful that neither water nor dirt are mixed. Be
sure to close the case tightly each time you handle this product. If removing grease
when the grease removal section is hot, there is a risk of burning. Remove oil after
the grease removal section has been cooled down.
Cautions Use a tightly closed device, a machine or a local exhaust device. Since vapor
generated from this product is heavier than air, and the vapor lingers in the area, do
not diffuse vapor freely, and ventilate the work area well.
Safety precautions Avoid contact with flames, sparks, and hot products. Take static-electricity
measures. Wear non-conductive clothes and shoes. Use flame proof electric
devices (with safety structure). Do not apply pressure to an empty container.
Applying pressure may cause disruption. Do not weld, heat, perforate or cut
container. Otherwise residual product may generate fire with an explosion.
■Storage
Appropriate storage
conditions
Avoid direct sunlight. Store oil in a ventilated space. Avoid heat, sparks, flames and
accumulation of static electricity. Do not generate vapor freely. The electric product
used in a storage space must be flameproof. Earth the electric products. Avoid
contact and storage of oil with halogen, strong acid, alkali, and acid products.
Safety package
materials
Use a container complying with [Article 3-2 of the separate volume of rules and
regulation of hazardous products].
Reference

NPM-W2 EJM7DE-MB-15M-00
Maintenance
16-2
Safety data sheet (SDS) 2
(LCG100)
16-2-3
Exposure controls/Personal protection
Machine
measurements
If mist or vapor is generated, shut the source out, or provide exhaust ventilation.
Ensure that eyewash stations and safety showers are proximal to the work-station
location.
■Tolerated concentration
Controlled
concentration
No regulations (Working environment evaluation standards: Ministry of Health,
Labor and Welfare Notice No. 26 March 27, 1995)
Tolerated
concentration
Japan Society for Occupational Health (2004 version)
Time load average TWA 3 mg/m
3
(for mineral mist oil)
ACGIH (2004 version)
Time load average TWA 5 mg/m
3
(for mineral mist oil)
■Personal protection equipment
Respiratory protection If mist or vapor is generated, wear a gas (organic gas) mask as necessary. Wear an
air mask in a closed space.
Hand protection Wear oil-proof (impervious) protective gloves.
Eye protection If there are droplets, wear regular protective glasses.
Skin and body
protection
Wear oil-proof long-sleeve coat and safety shoes. Remove grease-contaminated
clothes and wash them thoroughly before wearing.
Appropriate hygiene
measures
Do not eat, drink or smoke while working. Use hand-and eye-wash stations and
wash hands and face with plenty of water after handling this product. Do not take
contaminated gear such as gloves with you into a break room.
■Appearance
Physical state Solid
Color Brown
Order Characteristic
PH Not applicable
■Certain temperature/temperature range at which physical condition is changed
Boling point 200ºC or more (Initial boiling point)
Melting point No effective data currently available
Flash point 200ºC or more (Setaflash)
■Explosive properties
Explosion limit
Lower limit : 1 capacity %
Upper limit : 7 capacity % (Estimation)
Density No effective data currently available
Solubility Insoluble in cold water
Physical and chemical properties