N7201A617E00_0317 - 第57页

NPM-W 2 EJM7DE-SF-01N-0 0 1-4 -6 Confirmation

100%1 / 572
NPM-W2 EJM7DE-SF-01N-00
Precautions 3
1-4-5
1-4
Front side
In order to prevent the components being picked up from falling, the vacuum pump motor is designed
not to stop even if the emergency stop switch is pressed.
Handling of motors
Handling of connectors
When the emergency stop switch is pushed, the following motors are stop.
X-axis and Y-axis motors
Head Z-axis and θ-axis motors
Conveyor motor
Width adjustment motor
The following connectors do not cut off the power.
Power connector for the CPU BOX
Power connector for trays
Power connector for the Inspection BOX
(Inside of the machine)
Vacuum pump
NPM-W2 EJM7DE-SF-01N-00
1-4-6
Confirmation
NPM-W2 EJM7DE-SF-01N-00
Precautions 4
1-4-7
1-4
Handling of the height sensor
The height sensor complies with the class 1 (IEC60825-1) level of the laser safety standard, so it is
basically safe under the normal use. Do not directly look into during maintenance or operation.
Never look it into directly.
Item Laser specifications
Manufacturer Panasonic Factory Solutions Co., Ltd.
Model
number
N610112849AA
Wavelength 655 nm
Output 220 μW
Class Class 1
Installation
position
See P.1-4-8
Regulation IEC60825-1 2007
Height sensor specifications
The height sensor can be installed to the X-unit in the front and rear of the machine.
Output of laser elements is maximum of 220 μW. The sensor head does not have mechanism to stop
emission of the laser beam when disassembled. If disassembled, you may be exposed by laser radiation.
Never disassemble the sensor head.