00195364-0102_Ext_Power_COT_D1_D2_D3_HF - 第27页
SIPLACE 2 External power supply unit for component trolleys from the SIPLACE D1/D2/D3/HF series 11/2006 Edition 27 2.7 Technical data 2.7.1 Compressed air Input pressure: max. 10 bar (= 1000 kPa) 2 Output pressure: 2.5 b…

2 External power supply unit for component trolleys from the SIPLACE D1/D2/D3/HF series SIPLACE
11/2006 Edition
26
2.6.3 Changing the fuse
2
Fig. 7 Power switch with fuses
: Switch the power switch to OFF and make sure that the power plug is not plugged into the de-
vice connector.
: Release the snap closure of the fuse holder by pushing it up and pull the fuse holder and fuses
out of the drawer.
: Remove and check the two fuses and replace them if necessary.
: Only use type 5x20 mm / medium time-lag 6.3 Amp fuses (e.g. 03048168-01).
: Push the fuse holder with the two fuses back into the drawer until the snap closure latches.
Fuse holder
drawer
Power switch
Device plug
Fuses
Fuse holder
Snap closure

SIPLACE 2 External power supply unit for component trolleys from the SIPLACE D1/D2/D3/HF series
11/2006 Edition
27
2.7 Technical data
2.7.1 Compressed air
Input pressure: max. 10 bar (= 1000 kPa) 2
Output pressure: 2.5 bar (= 250 kPa) 2
2.7.2 Mains connection
2.7.3 Weights / dimensions
Weight: 4.3 kg 2
Dimensions: W x D x H = 180 x 360 x 210 mm 2
2
2
Voltage
88 - 264 VAC
Frequency
47...63 Hz
Rated current
5A / 115 VAC 2.5A / 230 VAC
Fuses
6.3A MT (medium time-lag)
2 External power supply unit for component trolleys from the SIPLACE D1/D2/D3/HF series SIPLACE
11/2006 Edition
28