Edition 4.0 H08M(Q) Head Repair Training Text
FK-9F98-86-0E 5-9 FUJI MACHINE MFG. CO., LTD.
9. After loosening the bolts above, adjust the position of the camera so that the resolution,
center and tilt values are all within the tolerance shown in the table below. Once they
are within tolerance, tighten the bolts.
10. Press the lower button to save the settings. Once the settings have been saved, press
the upper button to enter Adjustment Mode 2.
11. Remove the jigs
Inspection item Tolerance
LED current adjustment
Adjust the current value so that the GR and GL gray values
are within the range 95 to 250. The target value is 100 +/-
5. Current = 26 mA or below.
Camera resolution
check
L: X = 90 ~ 100
L: Z = 90 ~ 100
Center value R: Xs = 390 ± 20 Zp = 320 ± 20
L: Xp = 90 ± 25 Zp = 320 ±10
Tilt R: dX = 0~9 (Target: 0), dZ = 0~9 (Target: 0)
L: dX = 0~9 (Target: 0 , dZ = 0~9 (Target: 0)
Resolution values
Center values
Tilt values
CONFIDENTIAL
Edition 4.0 H08M(Q) Head Repair Training Text
FK-9F98-86-0E 5-10 FUJI MACHINE MFG. CO., LTD.
5.6 Adjusting the current value (grayscale value)
1. Press the lower button to display the current and grayscale values.
2. Rotate the R-axis by hand to find the positions where the grayscale values (GR and
GL) are maximized and minimized. Check that the minimum and maximum grayscale
values are within the tolerance shown below.
R: 90~170 Target: 100
L: 110~130 Target: 100
3. Also check that the current value is 26 mA or less, and the edge of a 0.3 mm nozzle
can be seen clearly.
4. Rotate the R-axis through one full rotation and confirm that there is no position where
the variation in the grayscale values (GR and GL) is extreme. Pay particular attention
to the variation in grayscale values at the position where the fluorescent sticker is
joined. If the variation is large, clean the fluorescent sticker and replace it if necessary.
CONFIDENTIAL
Edition 4.0 H08M(Q) Head Repair Training Text
FK-9F98-86-0E 5-11 FUJI MACHINE MFG. CO., LTD.
5. If the grayscale values are outside the target values, adjust them as shown below.
6. Press the upper button to select CURRENT, and then with either CURRENT UP or
CURRENT DOWN selected, press the lower button to raise or lower the CURRENT
value.
7. With either CURRENT UP or CURRENT DOWN selected, press and hold the lower
button.
8. An asterisk mark (*) displays next to the “R CURRENT” value only. The lower button
can now be used to adjust the R Current value separately.
9. Press and hold the lower button to display an asterisk mark (*) next to the “L
CURRENT” value. The lower button can now be used to adjust the L CURRENT value
separately.