Service Engineer Service I nformati on SI080 4004 E-000 = YS12 , YG12: Procedure for adjustmen t after installa tion of the mach ine 36/60 3. Start APC mounting m easurem ent. After changing the file name, c lick on the …

Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
35/60
[Items to be adjusted]
- Fiducial camera position (XY)
- Digital 3_Head 1 –10 Precision Zigzag parameter (X, Y): Main nozzle
- Digital 3_Head 2 –10 Precision Parallel parameter (X, Y): Main nozzle
5.2.2. Mounting and measurement performed by ACP
When completing the initial setup and the setting, please perform ACP adjustment.
Though the adjustment is normally performed by [All] function, if the mounting is interrupted and
restarts, please click on the [All] button again or click on the [Auto Run] button.
When the measurement is interrupted and perform only measurement, please click on the
[Measure] button.
1. Click on the [All] button on the “AutoRun/Measure” tab.
After checking the setting of the ACP adjustment and initial setup of the glass board, click on
the [All] button.
Figure 48
2. Save the measured result and input the file name
Click on the [All] button to display the screen to input the file name of the measured data.
Figure 49
[The name of the file for saving the adjustment data]
The default file name indicates the adjustment method and the item to be adjusted, so you just
need to add the date of the adjustment before the extension (.dat) and save the data.
Save
in:
Recently used file
Desktop
My Document
My Computer
My Network
File Name (N):
Save as type (T):
Save (N)
Cancel
ACP_Y20382_a_SC1_301_All_080318.dat
(*.dat)

Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
36/60
3. Start APC mounting measurement.
After changing the file name, click on the [Save (S)] button to perform mounting and
measurement in sequence.
Figure 50
4. Display the measured result. (“AMF Index” tab)
When the measurement is completed, the “AMF Index” screen is displayed.
If the measured result of “AMF index 1” is 1.0 or above, the adjustment does not need to be
performed.
If the result falls below “1.0”, the field turns red. Also the lowest Index value of each head is
indicated by boldface.
Figure 51
5. Check the values of the “AMF Index 1” and “AMF Index 2”.
Fill in the data as “The data before feedback” on the check sheet.
6. Click on the [VgChart] button.
Click on the [VgChart] button to check the adjustment state with the graphs.
Please refer to” 6.3 How to analyze the “VgChart” for how to interpret the graphs.
1.093 1.329

Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
37/60
When the measured result of “AMF index 1” is 1.0 or above;
As it indicates that the mounting accuracy is within specification, adjustment does not need to
be performed.
However, it is recommended to perform feedback of the compensation value to increase the
accuracy.
Fill in the Index value after adjustment as “The data after feedback” on the check sheet.
Move on to the next process:
- If the machine is equipped with the multi camera: Move on to “0.7. Accuracy adjustment of the
multi camera (Option)’.
- If the machine is not equipped with the multi camera: Move on to “8. Items to be adjusted
relating to the mounting accuracy of the machine”
When the measured result of “AMF index 1” falls below 1.0.
If the result falls below “1.0”, the lowest Index value of each head is indicated by boldface.
Please perform adjustment referring to the next section “6. If “AMF index” falls below
1.0.when performing accuracy check by ACP”.