1. Before replacement
Please make sure to check the following for safety before performing the adjustment.
1) All the fixing brackets are removed from the axes, and no removed brackets are left in the
machine.
2) The levels are not left in the machine.
3) The machine signal tower and the harness of the signal tower are properly secured.
4) There are no tools or foreign objects left in the machine, and also no interference exists
between the axes, head and other parts.
5) The primary power source of the machine is properly connected.
6) The primary air is properly supplied, there is no air leak and the air pressure is normal.
2. Required tools for adjustment
2.1. Tools for “Brightness adjustment”
<For the fiducial cameras and the multi cameras>
Part No. Part Name Size Feature
KM1-M8806-0XX
LIGHT ADJUSTER
35mm
square
Dark and light gray + white
KM1-M8806-1XX
LIGHT ADJUSTER 1
35mm
square
Dark and light gray + white,
With a Φ3 hole
KGT-M8806-0XX
LIGHT ADJUSTER S
17mm
square
Light gray and white
KHW-M8806-XXX
LIGHT ADJ.*(1,S, 3,4)
ASSY
35mm
square
Dark and light gray + white,
With one chamfered corner
<For the scan cameras>
Part No. Part Name Size Feature
KHW-M8806-D0X
LIGHT ADJ.4 ASSY
11mm
square
Light gray and white
Table 1
Figure 1
2.2. Glass board for adjustment
(If the ACP board cannot be prepared, use the AMF board)
Board type
Part Number Part Name Board data
Double-faced
tape to be used
ACP
Glass board
KM0-M8810-400
GLASS PCB
ASSY.4
ACP_1005_10HEAD_FL.ygx 20mm width
AMF
Glass board
KM0-M8810-100
GLASS PCB
ASSY.1
ACP_1005_10HEAD_OLD.ygx
35mm width
Table 2

Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
4/60
< ACP Glass board> < AMF Glass board>
Figure 2
2.3. Component for mounting adjustment
Component Part No. Part Name
1005 Ceramic chip (reel) KGA-M880C-10* REEL CERAMIC 1005
Table 3
2.4. Tools used for multi camera adjustment (Option)
Adjustment using the QFP68 pin and FAMF station needs to be performed in addition to the ACP
adjustment using the 1005 chip components.
FAMF Station
(240*170)
KGA-M88F0-A0X
FAMF STATION
ASSY.
Glass QFP68
Pin
KW8-M880A-10X
GLASS QFP 68P
Board data FAMF_QFP68_ST_H48.ygx
Table 4

Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
5/60
2.5. Other required tools
Some tools (nozzle) for adjustment may not come with the machine depending on the
specifications of the customer’s machine. Also, some basic adjustment may need to be performed
depends on the adjustment result.
The following tools are required for those adjustments.
Type
303A/314A
nozzle
(For SOP)
KHY-M7740-A0X
NOZZLE
303A/314A
AS
It needs to
be prepared
if the
machine is
not
equipped
with ANC
and the
nozzle is not
purchased.
Type
304A/315A
nozzle
(For QFP)
KHY-M7750-A0X
NOZZLE
304A/315A
AS.
It needs to
be prepared
if the
machine is
equipped
with the
multi
camera and
the nozzle is
not
purchased
4mm square
nozzle for
adjustment
KHN-M88N1-00X
JIG,
NOZZLE R
Used for
checking
the head
angle
Glass
QFP16 Pin
(With a
white sticker
on the back)
KHY-M880A-00X
GLASS
QFP 16
ASSY
Glass QFP
for adjusting
the scale
of the scan
camera
Jig used for
checking
the pick up
position of
the feeder
Under
development
FEEDER
JIG ASSY.
For YS12
Jig used for
checking
the pick up
position of
the feeder
KM8-M34E0-B1X*
FEEDER
JIG ASSY.
For YG12
Table 5