YS12调整 - 第6页

Service Engineer Service I nformati on SI080 4004 E-000 = YS12 , YG12: Procedure for adjustmen t after installa tion of the mach ine 6/60 3. The flow of the adjustment <The basic flow of th e “Preparation for the mo u…

100%1 / 60
Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
5/60
2.5. Other required tools
Some tools (nozzle) for adjustment may not come with the machine depending on the
specifications of the customer’s machine. Also, some basic adjustment may need to be performed
depends on the adjustment result.
The following tools are required for those adjustments.
Type
303A/314A
nozzle
(For SOP)
KHY-M7740-A0X
NOZZLE
303A/314A
AS
It needs to
be prepared
if the
machine is
not
equipped
with ANC
and the
nozzle is not
purchased.
Type
304A/315A
nozzle
(For QFP)
KHY-M7750-A0X
NOZZLE
304A/315A
AS.
It needs to
be prepared
if the
machine is
equipped
with the
multi
camera and
the nozzle is
not
purchased
4mm square
nozzle for
adjustment
KHN-M88N1-00X
JIG,
NOZZLE R
Used for
checking
the head
angle
Glass
QFP16 Pin
(With a
white sticker
on the back)
KHY-M880A-00X
GLASS
QFP 16
ASSY
Glass QFP
for adjusting
the scale
of the scan
camera
Jig used for
checking
the pick up
position of
the feeder
Under
development
FEEDER
JIG ASSY.
For YS12
Jig used for
checking
the pick up
position of
the feeder
KM8-M34E0-B1X*
FEEDER
JIG ASSY.
For YG12
Table 5
Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
6/60
3. The flow of the adjustment
<The basic flow of the “Preparation for the mounting adjustment” after installing the
machine>
Figure 3
Installation of the machine
System data backup
Y-Axis dual drive
Offset adjustment
Adjust
“Orthogonalization level”
Check the parallelism
and the width of the
conveyor
Adjust the brightness of
each camera
Move on to
“Mounting Adjustment”
NG
Fiducial Camera
Relative Pos (Option)
Safety check
Check the status
and take measures
Turn on the machine
Measure the height of
the board surface
Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
7/60
<The basic flow of the “Mounting adjustment” after installing the machine>
Figure 4
Prepare for the accuracy check of
the reference nozzle with ACP.
Perform accuracy check of the
r
eference nozzle with ACP
Please refer to “6.1. The workflow
when
“AMF Index” falls below 1.000”
<Readjustment of the items related
to mounting accuracy>
- Camera scale of the fiducial camera
- The camera scale of the scan camera
- Positioning of the scan camera
-Head Offset XY
<Check the other functions>
- Check if the board is transferred from the
upstream machine to the down stream
machine smoothly.
- Check the pickup position of the feeder plate.
- Check the operation of the blow station.
- Check the “PCB origin”.
- Check the vacuum level.
- Check the operation of the “Nozzle change”
function (Option)
- Check the operation of the feeder exchange
carriage (Option)
Perform adjustment of the
reference
nozzle with ACP
Check the value of “AMF
Index” after adjustment.
Does the value meet the
specification?
Check the value of AMF Index
Complete
mounting
adjustment
Save the data as the accuracy
before adjustment after
relocation of the machine.
Save the value as
the accuracy after
adjustment
.
Investigate the cause of
the problem
NG
OK
Does the value of
AMF Index meet
the specification?
Save the measured result
of the mounting accuracy
Save the result of the mounting
accuracy after adjustment.
Check the accuracy of the
multi camera and perform
adjustment (Option)
NG