LmrXP142机械手册.pdf - 第79页

3.3 Replacing the Filter of the V acuum Generator Used for Gauge Chip Part Pick-up (Every Y ear) Point The vacuum generator used for gauge chip part pick-up is equipped with a dust filter. This filter should be replaced …

100%1 / 145
3.2 Replacing the Conveyor Belt
Procedure
WARNING
Cut power to the machine at the main switch before
attempting this procedure.
1. Loosen the set screws on the pulley rod, and slide the rod in the direction of the
arrow.
2. Loosen the belt tension pulley.
3. Remove the In-Station and Main-Station side plates.
4. Removal of the conveyor top plate is not necessary. At the end of the conveyor,
pull a small section (about 5 mm) of the conveyor belt off of the guide.
5. Manually pull the conveyor belt in the reverse direction to remove the conveyor
belt. The derailed section of the belt will slide to the opposite end of the conveyor.
6. Use the reverse procedure to install the new belt. Engage a small section of the belt
and pull the belt so that the engaged section slides to the opposite end.
7. Return the pulley rod and tighten its set screws.
8. Tighten the tension pulley bolt, using a tension meter (Hz) to adjust the tension as
shown below.
9. Return the In-Station and Main-Station side plates.
Conveyor belt tension tolerance (frequency): 425 ~ 445 Hz
Measurement position: Midway between the conveyor belt drive pulley and the
tension pulley (approximately 50 mm).
Tension pulley tightening torque: 3.0 N·m
Tension pulley
Approx. 50 mm
Belt tension
measuring position
Drive pulley
XP1MR204E
XP1MR202E
Fixed rail
Set screw
Rod
Part 3 Chapter 3 Replacing Consumable Parts
Edition 3.1 3-3-3 XP-142E Mechanical Reference
3.3 Replacing the Filter of the Vacuum Generator
Used for Gauge Chip Part Pick-up (Every Year)
Point
The vacuum generator used for gauge chip part pick-up is equipped with a dust filter.
This filter should be replaced regularly to ensure stable part holding.
Procedure
WARNING
Cut power to the machine at the main switch before
attempting this procedure.
1. Turn the filter counterclockwise to remove.
2. Replace the old filter element with a new one.
XP1MR205E
Filter element
Filter of vacuum generator
used for gauge chip
part pick-up
Filter case
Part 3 Chapter 3 Replacing Consumable Parts
Edition 3.1 3-3-4 XP-142E Mechanical Reference
3.4 Replacing the Mark Camera Lamp
Point
The mark camera lamp should be replaced when it burns out, or when its brightness
dims.
Procedure
1. Detach the MFU if so equipped.
2. Press the EMERGENCY STOP button to turn the 200 V power off.
WARNING
Press EMERGENCY STOP button to cut power to the
machine before attempting this procedure.
3. Move the placing head by hand to the front of the machine.
4. Remove the dispersion plate.
5. Turn the output [ON] to check if any lamps are burnt out.
6. Remove the burnt lamp from the socket.
7. Insert a new lamp in the socket, then mount the dispersion plate.
Note: The replacement procedure is easier if a small mirror is used to verify the lamp and
socket positions.
XP1MR208E
Dispersion plate
Lamp
Socket
Part 3 Chapter 3 Replacing Consumable Parts
Edition 3.1 3-3-5 XP-142E Mechanical Reference