00196715-04_IM_SSW_704_03_SP1_DE_EN - 第22页
Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition 4.2.2 Machine/Vision computer (i n one-computer operation) Name SIMATIC Box PC 627B CPU / clock frequency Core 2 Duo T7400 / 2,16 GHz RAM 1 GB Har…

Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition
4.2.1 Machine/Vision computer (in two-computer operation)
Name SIMATIC Box PC 627
CPU / clock frequency Pentium M 760 / 2 GHz
RAM 1 GB
Hard disk Yes
External DVD drive pluggable via USB
Serial interfaces 1
USB interfaces and
external USB hub
Yes
Network 2x 100 MBit
Table 4-3: Machine/Vision computer hardware SIPLACE X-series
Name SIMATIC Box PC 627B
CPU / clock frequency Core 2 Duo T7400 / 2,16 GHz
RAM 1 GB
Harddisk Yes
External DVD drive pluggable via USB
Internal DVD drive No
Serial interfaces 1
USB interfaces and
external USB hub
Yes
Network 2x 100 MBit
Table 4-4: Machine/Vision computer hardware SIPLACE X-series
21

Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition
4.2.2 Machine/Vision computer (in one-computer operation)
Name SIMATIC Box PC 627B
CPU / clock frequency Core 2 Duo T7400 / 2,16 GHz
RAM 1 GB
Harddisk Yes
External DVD drive Yes
Internal DVD drive No
Serial interfaces 1
USB interfaces and
external USB hub
Yes
Network 2x 100 MBit
Table 4-5: Machine/Vision computer hardware SIPLACE SX1/2
Name SIMATIC Box PC 827B
CPU / clock frequency Core 2 Duo T7400 / 2,16 GHz
RAM 2 GB
Harddisk Yes
External DVD drive No
Internal DVD drive No
Serial interfaces 1
USB interfaces Yes
External USB hub No
Network 2x 100 MBit
Table 4-6: Machine/Vision computer hardware SIPLACE X-series and SX4
22

Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition
4.3 Network configuration
Figure 4-5: Network connections between the machine and SIPLACE Pro
In two-computer operation a separate private network (100 Mbit/s) is set up between the machine
computer and the Vision computer via a subnet mask.
Fixed IP addresses for the machine computer and the Vision computer can thus be assigned for all
SIPLACE machines. These IP addresses are not known outside the private network, for instance in
the SIPLACE LAN or customer LAN.
These IP addresses need not be further configured by the operator while the station software is
being installed.
23