Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition When you have selected all table config urations the following window is displayed, in which you confirm the Auto-configuration. Figure 7-8: Confi…

Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition
► Repeat the steps for Location 1.
Settings for manual tray Carrier SX
If the manual tray Carrier SX is used, the insert frame with the fold-away tape guide channel is
required. This has to be set manually. In this case, the following selectable table configurations are
displayed:
Figure 7-7: Settings for manual tray Carrier SX
► Select the 60 slots (outer position, fold-away tape duct) table configuration.
► Click the Accept button.
Thus, the 27x27 reject bin and the left reject channel on the location are excluded from the
configuration.
CAUTION
If this setting is not made, the component may be rejected over the tray and the Z axis
may dash hard against the tray.
► Repeat the steps for Location 1.
43

Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition
When you have selected all table configurations the following window is displayed, in which you
confirm the Auto-configuration.
Figure 7-8: Confirming Auto-configuration for SX1/SX2
► Click the Confirm changes and continue startup button to confirm the Auto-configuration.
7.3 SX+ placement machine
If the SX+ placement machine is to be used without gantries, this has to be configured in the Auto-
configuration after the machine has been booted. For this you have to select Ignore gantries at
the processing area in the machine configuration dialog.
7.4 SX4 placement machine
When the SX4 placement machine is booted for the first time you have to select the SX4 Flexible
entry for Machine frame manually in the Auto-configuration, if there are tables in outer position in
processing area 2, as this is not detected automatically via sensors. Tables in outer position are
used when stationary cameras are in use. Otherwise you select the SX4 High Speed entry.
44
Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition
7.5 Checking/Updating the embedded software
If the correct eSW versions are not available on the machine, the machine boot gets interrupted.
► In this case, perform an eSW download.
► Start an overall reference run for the machine.
7.6 Storage location of the machine files (calibration data etc.)
The machine-specific configuration, measurement and parameter data is stored in XML files under
C:\Sirio\Work\Individual. These XML files contain all the calibration data.