3 Upgrading to the 704.03 SP1 software version
This chapter describes which steps you have to attend when upgrading from different software
versions.
When upgrading the station software, always check the eSW versions and download the current
versions if necessary.
NOTICE
With the installation of the 704.03 SP1 station software, statistic data (maintenance
intervals) is registered for the CPP placement head and the SX main axis. In order to
achieve a defined initial state for the maintenance due, the correspondent
maintenance operations have to be performed on the subsystems after the software
installation.
An upgrade of the embedded software is necessary for the LDU-X. Generally, it is
not possible to perform a download of the embedded software via the station
software for the LDU-X. The LDU-X has to be upgraded to the 2.02 software version
with the aid of an external PC.
3.1 Upgrading from the 704.xx software version
Recalibrate the travelling ranges.
The travelling range measurement has been improved in 704.03 SP1. For this reason you are
advised to recalibrate the travelling ranges during installation of the 704.03 SP1 station
software.
Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
Save the calibration data for the placement heads (except Twin Head) in the EEPROM
(see section 7.8).
Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
3.2 Upgrading from the 703.02 or 703.02 SP1 software versions
Please pay attention to the Technical Informations TI2010-10V02 and TI2010-10C02 when you
download the embedded software.
Recalibrate the travelling ranges.
Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
SX-series placement machines in the field:
Due to the SW component counter, the HCU/GCU and the sensor modules have to be
programmed. For this, perform the work steps that are described in the Technical Informations
TI2010-02V01 and TI2010-02C01 about programming HCU/GCU for the 704 upgrade. These
work steps can only be performed by SIPLACE Service.
8
Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition
SX 1/2 placement machine:
In order to use the "Long Board" option and the "Gantry Modularity" functionality, PCB mapping
and head mapping have to be performed.
Placement machines with FC camera:
The entire placement head has to be calibrated.
X4I placement machine:
The machine zero points, tables, nozzle changers, PCB reference corners and, if stationary
cameras are present the placement heads as well, have to be recalibrated (due to a changed
handling of double zero points on the X4I placement machine). No mapping is necessary.
Save the calibration data for the placement heads (except Twin Head) in the EEPROM
(see section 7.8).
3.3 Upgrading from the 703.01 software version
Please pay attention to the Technical Informations TI2010-10V02 and TI2010-10C02 when you
download the embedded software.
Recalibrate the travelling ranges.
Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
3.3.1 SX-series placement machines
SX-series placement machines in the field:
Due to the SW component counter, the HCU/GCU and sensor modules have to be
programmed. For this, perform the work steps that are described in the Technical Informations
TI2010-02V01 and TI2010-02C01 about programming HCU/GCU for the 704 upgrade. These
work steps can only be performed by the SIPLACE Service.
Exchange the X/Y sensor modules to X-03068500-03 / Y-03064608-03.
Install the 704.03 SP1 station software.
Shut down the machine.
Remove the tables.
Switch on the machine again and wait until all error messages have been displayed and the
eSW download menu is enabled.
Perform the eSW download for all subsystems.
Reboot the machine.
Place the tables.
The eSW download for the feeders starts automatically.
Save the calibration data for the placement heads (except Twin Head) in the EEPROM (see
section 7.8).
Calibrate the machine by performing the following steps:
Calibrate the gantry axis (activate the options Y-axis: Encoder Alignment, Travel range,
X-axis: Parameterization, Y-axis: Mapping in the list).
Perform PCB and head mapping.
Start the production.
9
Station Software 704.03 SP1 / Installation Manual Ausgabe 10/2011 Edition
3.3.2 X-series placement machines
Install the 704.03 SP1 machine computer software for two-computer operation, see chapter 5.
Install the Vision computer software, see chapter 6.
Shut down the machine.
Remove the tables.
Switch on the machine again and perform the eSW download.
Reboot the machine.
Place the tables.
The eSW download for the feeders starts automatically.
Save the calibration data for the placement heads in the EEPROM (see section 7.8).
Start the production.
3.4 Upgrading from 701.xx software versions (X4I placement
machine)
Download the SIPLACE_UpgradePreparation.exe file (directory Upgrade_Preparation) from the
installation CD and execute the file.
Reboot the machine and perform an eSW download for the placement heads.
Install the 704.03 SP1 machine computer software for two-computer operation, see chapter 5.
Install the Vision computer software, see chapter 6.
Shut down the machine.
Remove the tables.
Switch on the machine again and perform the eSW download.
Reboot the machine.
Place the tables.
The eSW download for the feeders starts automatically.
Save the calibration data for the placement heads in the EEPROM (see section 7.8).
Calibrate the nozzle changer.
Calibrate the conveyor.
Start the production.