00191134-03 - 第10页
GEM for SIPLACE V5.01 Page 10 of 252 ©Siemens AG, all rights reserved Changes fr om Hos t Interfac e Manual V3.02: • Definition of Data Item 'Com pLeft2Plac e' correc ted The SEMI Equipm ent Com m unication Sta…

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 9 of 252
,QWURGXFWLRQ
This document describes the SECS interface version 405.xx provided on the SIPLACE.
Changes from Host Interface Manual V2.0:
•
Section 4.2: Documentation of Data Items corrected: PickUpResult, PlacementResult
•
Section 4.9: Documentation corrected: PPBODY is a binary data block
•
Section 6: Documentation corrected: PICKUPERRORS (VID 2012019)
•
Section 8: New Collection Events: PCBstartProcessing (CEID 2010013),
MachineReStarted (CEID 2010015)
Changes from Host Interface Manual V3.01:
•
Section 4.2: Documentation of Data Items corrected.
•
Section 6: New Variables: COMPONENTBARCODE (VID 912003),
WAYOFINPUTCOMPONENTBARCODE (VID 912004), MACHINESIDE (VID
2012022), TRACKNUMBER (VID 2012023), DIVISION (VID 2012024), LEVEL (VID
2012025), SEGMENT (VID 2012026), COMPONENTNAME (VID 2012027),
GANTRYID (VID 2012028), GROUPGANTRYID (VID 2012029), HEADID (VID
2012030), REFERENCEDESIGNATOR (VID 2012031), PACKAGEFORMNUMBER
(VID 2012032), PLACEERRORDESCPIPTION (VID 2012033),
GEMTIMEFORMAT(VID 1002065)
Variable TIME (VID 1002023) changed
•
Section 6: Documentation corrected: PLACEINFOREV1 (VID 1312004),
PLACEINFOREV2 (VID 1412003), PLACEINFOIC (VID 1512014) and oder of VID’s
corrected.
•
Section 7: New Predefined Reports: BeBarcode(RPTID 27), PickUpError (RPTID 28),
PlaceError (RPTID 29)
•
Section 8: New Collection Event: ComponentBCread (CEID 920002), PickUpError
(CEID 2010016), PlaceError (CEID 2010017)
Changes from Host Interface Manual V3.02:
•
Section 3.1.9: Description of Control State (Online/Local) completed
•
Section 4.2: Documentation of Data Items corrected.
•
Section 6: Order of the Variables corrected. New Variables:
PCBSIDEININPUTCONVEYOR(VID 912005), PCBSIDEINCENTERCONVEYOR
(VID 912006), BCINTWINCENTERCONVEYOR (VID 912011),
BCINTWININPUTCONVEYOR (VID 912012), PCBSIDEINTWININPUTCONVEYOR
(VID 912015), PCBSIDEINTWINCENTERCONVEYOR (VID 912016),
BCREADEREXIST (VID 912017), SOFTWAREREVGEM (VID 1002067)
Description of HEIGHTREVOLVER1 (VID 1312001) and HEIGHTREVOLVER2 (VID
1412001) changed
Names of Variables corrected: TRANSPORTWIDTH, GANTRYONERROR
(correction in manual)
GUINOZZLETYPE VID corrected to 11220006 (correction in manual)
STIME format corrected in this manual: S6F1 description
• Section 7:
Predefined Reports expanded: Nozzle1(RPTID 14), Nozzle2 (RPTID 15)
Predefined Reports deleted: RefRunHead1(RPTID 19), RefRunHead2 (RPTID 20)
New Predefined Reports: BarcodeTwin (RPTID 30)
• Section 8: New Collection Event: BCTwinRead (CEID 920011)

GEM for SIPLACE V5.01
Page 10 of 252 ©Siemens AG, all rights reserved
Changes from Host Interface Manual V3.02:
•
Definition of Data Item 'CompLeft2Place' corrected
The SEMI Equipment Communication Standard (SECS) is published by Semiconductor
Equipment and Materials International (SEMI). It defines a computer to computer
communications interface between a unit of factory Equipment and a Host Computer.
This Equipment complies to the SECS-II standard, all SECS-II message used in GEM are
implemented. The SIPLACE complies to the following versions of standards:
E5-1994 (SECS-II)
SEMI Document #2758, Line 1 Item #1 (The Year 2000 issue)
6(&6,,&ODULILFDWLRQV
SIPLACE GEM is Year 2000 compliant according to the new Year 2000 SECS-II Standard
(SEMI Document #2758, Line 1 Item #1).
The SIPLACE uses the following SECS-II conventions:
'DWD)RUPDW7\SHV
Where the Standards permit a choice of data item types, the choice has been made as
described in section „Message Detail“.
For outgoing messages, the Equipment always sends Data Items of the exact format
shown. For some incoming messages, the Equipment „forgives“ minor host errors. For
example, the Equipment may accept a U1 Data Item where a U2 format was expected.
We recommend the Host attempt to use the formats shown.
'DWD,WHP/HQJWK%\WHV
For messages sent by the Equipment, the number of length bytes in Data Items is always
the minimum required to contain the Data Item length.
For messages received from the Host, the number of length bytes in Data Items can be 1,
2, or 3, provided that the length parameter can accurately be specified.
$6&,,'DWD
Unless otherwise specified, all ASCII data items must contain printable ASCII data—that
is, characters in the range 0x20 to 0x7E.
0XOWL%ORFN0 HVVDJHV
Wherever the Host is supposed to send a single-block message, this Equipment will also
accept multi-block format.
The maximum size for a single SECS message is approximately 1000 blocks (256,000
bytes).
)XQFWLRQ=HUR
The Equipment sends a Reply Message using Function zero (F0) according to the
requirements of the GEM Control State.
Wherever this Equipment expects a Reply message from the Host, the Host can send F0.
The Equipment will instantly abort the outstanding transaction. The Equipment will not
take any additional action.
*(0 6WDQGDUG
The SEMI Generic Equipment Model for Effective Factory Automation (GEM) is another
document published by SEMI. The GEM standard defines some useful conventions for
designing the communications interface on a unit of factory Equipment to improve

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 11 of 252
operations with a Host Computer. The SIPLACE complies to the following GEM
document:
1. E30-1994
*(0 &RPSOLDQFH
This section clarifies which GEM functions are implemented in this Equipment. See
„GEM Compliance Statement“ on page 12.
The SIPLACE never sends S2F25 (Loopback Diagnostic) to the Host. It will send the
appropriate S2F26 in response to an S2F25 from the Host.
The SIPLACE never sends S9F13 (Conversation Timeout) to the Host. The Equipment
can be defined as having an „infinite timeout“ for conversations.
The SIPLACE never sends S10F7 (Multi-Block Not Allowed) to the Host. It will accept
incoming messages consisting of printable characters and a maximum size of 320
characters.
The SIPLACE will accept, but does not require the Inquire/Grant transaction
(S2F39/S2F40, S6F5/S6F6, S7F1/S7F2) for incoming primary multi-block messages.