00191134-03 - 第103页
GEM for SIPLACE V5.01 ©Siemens AG, all rights r eserved page 103 of 252 6)$ ODUP5HSRUW%ORFN$ FNQRZOHGJH S5F73 [W ] * H<-E <L [3] <U4 ALID> * ALID - Alarm ID <BOOLEAN AST AT > * T = Alar…

GEM for SIPLACE V5.01
Page 102 of 252 ©Siemens AG, all rights reserved
6)$ODUP5HSRUW%ORFN6HQG
S5F71 [W] * H<-E
<L [2]
<U1 0> * ALPY Alarm Priority
<L [1]
<L [4]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On
F = Alarm Off
<U4 ASER> * ASER Alarm Serial Number
<A [16] 'YYYYMMDDhhmmsscc'> * CLOCK
>
>
> .
1RWH7KLVPHVVDJHLVSURYLGHGRQO\IRUFRPSDWLELOLW\ZLWK+RVWFRPSXWHUVZKLFKVXSSRUW
DQROGHUYHUVLRQRI*(0
If the Equipment Constant "ConfigAlarms" is set to "1", the Equipment sends S5F71
instead of the normal S5F1 Alarm Notification Send.
The SIPLACE reports that an alarm condition has changed.
ALID identifies the Alarm.
ASTAT value is "True" (Non-zero) if this alarm is currently On (Unsafe), or "False" (Zero)
if it is currently Off (Safe).
ASER (Alarm Serial Number) is assigned by the Equipment. Its value begins at "1" and is
incremented by 1 for each alarm reported.
ALPY (Alarm Priority) is always zero.
CLOCK indicates the date and time of the alarm change.
Equipment Constant "Wbits5" controls whether the Equipment sends S5F71 with w-bit =
"1" (Reply Expected) or "0" (No Reply Expected).
6)$ODUP5HSRUW%ORFN$FNQRZOHGJH
S5F72 * H->E
<L> .
The Host acknowledges Alarm Report. This Equipment ignores the data portion of
S5F72.

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 103 of 252
6)$ODUP5HSRUW%ORFN$FNQRZOHGJH
S5F73 [W] * H<-E
<L [3]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On,
F = Alarm Off.
<A [16] 'YYYYMMDDhhmmsscc'> * TIMESTAMP
> .
1RWH7KLVPHVVDJHLVSURYLGHGRQO\IRUFRPSDWLELOLW\ZLWKROGHU+RVWFRPSXWHUVZKLFK
VXSSRUW*(0
In order for this message to be used, the Equipment Constant "ConfigAlarms" must be set
to "2".
The SIPLACE reports that an alarm condition has changed.
ALID identifies the Alarm.
ASTAT value is "True" (Non-zero) if this alarm is currently On (Unsafe), or "False" (Zero)
if it is currently Off (Safe).
TIMESTAMP indicates the date and time of the alarm change.
Equipment Constant "WBitS5" controls whether the Equipment sends S5F73 with W-Bit
"1" (Reply Expected) or "0" (No Reply Expected).
6)$ODUP1RWLILFDWLRQ$FNQRZOHGJH
S5F74 * H->E
<B [1] ACK5> .
The Host acknowledges Alarm Report. This Equipment ignores ACKC5.

GEM for SIPLACE V5.01
Page 104 of 252 ©Siemens AG, all rights reserved
6WUHDP
6)7UDFH'DWD6HQG
S6F1 [W] * H<-E
<L [4]
<U4 TRID> * Trace ID
<U4 SMPLN> * Sample Number
<A 'yyyymmddhhmmss'> * STIME - Sample Date and Time
<L
<V> * Variable Value
...
>
> .
The Equipment sends time driven trace data, as previously requested by the Host using
S2F23.
TRID is the Trace ID as initiated by the Host.
SMPLN is the sample number. The first sample is "1", the next "2", and so on. If
REPGSZ is greater than 1, SMPLN is the number of the last sample contained in this
S6F1.
STIME is the date and time at which this sample was taken. If REPGSZ is greater than 1,
STIME is the date and time of the last sample contained in this S6F1.
The V's appear in the same order they were specified in S2F23.
S6F1 is normally single block. However, if the Host erroneously initiates a multiblock
trace using an incorrect S2F23, S6F1 may be multi-block. The Equipment never sends
an Inquire/Grant message preceding S6F1.
Equipment Constant "WBitS6" controls whether the Equipment sends S6F1 with W-Bit "1"
(Reply Expected) or "0" (No Reply Expected).
6)7UDFH'DWD$FNQRZ OHGJH
S6F2 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the data. The Equipment ignores ACKC6.
6) $QQRWDWHG(YHQW5HSRUW
S6F3 [W] * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 DSID> * DSID=RPTID Report ID
<L