GEM for SIPLACE V5.01 Page 106 of 252 ©Siemens AG, all rights reserved S6F5 W * H<-E <L [2] <U4 DATAID> * DATAID <U4 DATALENGT H> > . The Equipm ent sends this Inquire/Gr ant transaction pr eceding a…

100%1 / 245
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 105 of 252
<U4 VID> * Variable ID
<V> * Variable Value
>
...
>
>
...
>
> .
1RWH7KLVPHVVDJHLVSURYLGHGRQO\IRUFRPSDWLELOLW\ZLWKROGHU+RVWFRPSXWHUVZKLFKGR
QRWVXSSRUW*(0
If the Equipment Constant "ConfigEvents" is set to "0", the Equipment sends S6F3 instead
of the normal S6F13 Annotated Event Report.
A Collection Event has occurred at the Equipment. The Host has enabled event reporting
for this CEID (see S2F37). The Host has set the Equipment constant RpType to "True"
(Annotated report format desired). The SIPLACE sends one or more Event Reports
which the Host has previously linked to that CEID (see S2F35). Each report contains
specific Variables which the Host has previously defined for that Report (See S2F33).
The Equipment generates a value for DATAID to uniquely identify this Conversation. If
S6F3 is multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction,
and DATAID in S6F3 will match DATAID in S6F5.
If the CEID is enabled, but no Reports are linked to this CEID, S6F3 has the following
special format:
S6F3 [W] * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
Equipment Constant "Wbits6" controls whether the Equipment sends S6F3 with W-Bit "1"
(Reply Expected) or "0" (No Reply Expected).
 6)$QQRWDWHG(YHQW5HSRUW$FNQRZOHGJH
S6F4 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignores ACKC6.
S6F5 - Multi-Block Data Send Inquire
GEM for SIPLACE V5.01
Page 106 of 252 ©Siemens AG, all rights reserved
S6F5 W * H<-E
<L [2]
<U4 DATAID> * DATAID
<U4 DATALENGTH>
> .
The Equipment sends this Inquire/Grant transaction preceding any multiblock S6F3,
S6F9, S6F11, or S6F13.
The DATAID specified here will appear in the following S6F3, S6F9, S6F11, S6F13.
DATALENGTH value is the total number of text bytes (excluding SECS block headers) in
the following S6F3, S6F9, S6F11, or S6F13 message.
 6)0XOWL%ORFN*UDQW
S6F6 * H->E
<B [1] GRANT6> . * GRANT6
The Host grants permission for the Equipment to send a multi-block event report..
GRANT6 Description
0x00 Normal. Permission granted.
Other Permission not granted. The Equipment will not
send the following S6F3, S6F9, S6F11, or
S6F13, and will discard the data.
 6)(YHQW5HSRUW
S6F9 [W] * H<-E, Multiblock
<L [4]
<B [1] 00> * PFCD
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 DSID> * DSID=RPTID Report ID
<L
<V> * Variable Value
...
>
>
...
>
> .
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 107 of 252
1RWH7KLVPHVVDJHLVSURYLGHGRQO\IRUFRPSDWLELOLW\ZLWKROGHU+RVWFRPSXWHUVZKLFKGR
QRWVXSSRUW*(0
If the Equipment Constant "ConfigEvents" is set to "0", the Equipment sends S6F9 instead
of the normal S6F11 Event Report.
A Collection Event has occurred at the Equipment. The Host has enabled event reporting
for this CEID (see S2F37). The Host has set the Equipment Constant RpType to "False"
(normal report format desired). The Equipment sends one or more Event Reports which
the Host has previously linked to that CEID (see S2F35). Each report contains specific
Variables which the Host has previously defined for that Report (see S2F33).
PCFD is always zero.
The Equipment generates a value for DATAID to uniquely identify this Conversation. If
S6F9 is multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction,
and the DATAID in S6F9 will match DATAID in S6F5.
If the CEID is enabled, but no Reports are linked to this CEID, S6F9 has the following
special format:
S6F9 [W] * H<-E
<L [4]
<B [1] 00> * PFCD
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
Equipment Constant "WBitS6" controls whether the Equipment sends S6F9 with W-Bit "1"
(Reply Expected) or "0" (No Reply Expected).
 6)(YHQW5HSRUW
S6F10 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignores ACKC6.