00191134-03 - 第164页
GEM for SIPLACE V5.01 Page 164 of 252 ©Siemens AG, all rights reserved 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ FALSE = Do Not Overwrite Spool Limit Monitor ing 1002047 DV U4 G EMLIMITSVID. The VID relating to…

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 163 of 252
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
have been overwritten or otherwise discarded.
1002039 SV U4 SPOOLCOUNTTOTAL.
A count of the number of messages the equipment
attempted to write to the spool disk. This number
includes messages actually present on the spool disk,
and also any messages which may have been
overwritten or otherwise discarded.
1002040 SV A[16] SPOOLFULLTIME.
The date and time at which the spool file became full.
Format is: YYYYMMDDhhmmsscc. See description
of CLOCK variable above for format details.
1002041 SV U1 SPOOLLOADSUBSTATE.
The current state within the SPOOL LOAD super-
state.
6 = Spool Not Full
7 = Spool Full
1002042 SV A[16] SPOOLSTARTTIME.
The date and time at which the first message was
written to the current spool file. Format is:
YYYYMMDDhhmmsscc.
See description of CLOCK variable above for format
details.
1002043 SV U1 SPOOLSTATE.
The current spool state within the POWER ON super-
state.
2 = Spool Inactive
1 = Spool Active
1002044 SV U1 SPOOLUNLOADSUBSTATE.
The current spool state within the SPOOL UNLOAD
super-state.
3 = Purge Spool
4 = Transmit Spool
5 = No Spool
1002045 EC U1 CONFIGSPOOL.
This EC determines whether spooling is enabled or
disabled for this Equipment.
0 = Disabled
1 = Enabled
1002046 EC BOOL OVERWRITESPOOL.
This EC determines the action to be taken by the
Equipment when the Spool file reaches its capacity.
TRUE = Overwrite Spool

GEM for SIPLACE V5.01
Page 164 of 252 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
FALSE = Do Not Overwrite Spool
Limit Monitoring
1002047 DV U4 GEMLIMITSVID.
The VID relating to the most recent Limits Monitoring
transition event which occurred.
1002048 DV B[1] GEMEVENTLIMIT.
The LIMITID relating to the most recent Limits
Monitoring transition event which occurred.
1002049 DV B[1] GEMTRANSTYPE.
Transition type relating to the most recent Limits
Monitoring transition which occurred.
0x00 = Lower -> Upper
0x01 = Upper -> Lower
1002050 EC U2 GEMLIMITSTIMER.
The time in seconds this equipment will pauses
between checking for Limits Monitoring transitions
On-Line Identification
1002051 SV A[6] MDLN.
Model number. Ä6ÄorÄ)Ä
1002052 SV A[6] SOFTREV.
Software revision number. [[
1002053 SV A SOFTWAREREVWPC
Software revision of the waffle pack changer
A value of 0 indicates an error.
1002054 SV A SOFTWAREREVTABLE
Revision of feeder table software
A value of 0 indicates an error.
1002055 EC U2 HEARTBEAT.
The time in seconds that the Equipment will pause
before sending S1F1 to test the link. Units are
seconds. Valid values are 0-3200 (a setting of zero
will disable the heartbeat).
1002065 EC U1 GEMTIMEFORMAT
Format of TIME (VID 1002023)
0: 12 digits
1: 16 digits (Year 2000 compliant)
1002067 SV A SOFTWAREREVGEM
Software revision of the GEM Kernel

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 165 of 252
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
GUI
1122001 SV A GUIACTIONTEXT
Last „Action text“ sent to GUI
An empty text indicates an error
1122002 SV A GUISTATETEXT
Last „State text“ sent to GUI
An empty text indicates an error
1122003 SV I2 GUISEGMENTNR
Segment number sent by GUI
A value of -1 indicates an error
1122004 SV I2 GUIGANTRYNR
Gantry number sent by GUI
A value of -1 indicates an error
1122005 SV I2 GUITRACKNR
Track sent by GUI
A value of -1 indicates an error
1122006 SV I2 GUINOZZLETYPE
Nozzle type sent by GUI
A value of -1 indicates an error.
SIPLACE Revolver Head 1
1312001 SV I4 HEIGHTREV1
Height of revolver head 1. Only valid after height
reference run. Units are 1/1000 mm
During the reference run the SIPLACE measures the
distance between the upper edge of the conveyor belt
and the nozzle on segment 1. The
HEIGHTREVOLVER1 is then calculated by subtracting
the length of the nozzle on segment 1 from the
measured value. The nozzle length is defined in the
machine data. So HEIGHTREVOLOR1 is a relative
not an absolute value.
A value of 0 indicates an error
1312002 SV L GANTRYINFOREV1
Gantry information for revolver head 1. The data is
automatically reseted when a PCB reaches the center
conveyor.
/
,&RP3LFNHG8S!
,&RPS3ODFHG!
,&RPS/HIW3ODFH!
!