00191134-03 - 第176页

GEM for SIPLACE V5.01 Page 176 of 252 ©Siemens AG, all rights reserved 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ Placem ent infor mation f or IC-head 2 O nly valid for SIPLACE 80F. On a SIPLACE 80S this var iab…

100%1 / 245
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 175 of 252
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
conveyor belt from the HEIGHTIC value.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1512010 SV L VACUUMDATAIC
Vacuum measurements IC-Head. Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
,RSHQBQR]]OH!
,FORVHGBQR]]OH!
,FXELFBQR]]OH!
,QRWBFXELFBQR]]OH!
,WROBGLUW\BQR]]OH!
,WROBOHDN\ BQR]]OH!
!
tol_dirty_nozzle and tol_leaky_nozzle are currently not
used.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1512013 SV L COPLANARITYDATAIC
Result of last coplanarity measurement. Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
$&RPSRQHQW1DPH!
83DFNDJH)RUP1XPEHU!
85HVXOW!0:Ok; 1:Error
,0D[/HDG'HY!>PP@
!
The coplanarity module measures the height of all
leads and calculates then a hypothetical plane through
the three highest leads. 0D[/HDG'HY is the greatest
deviation between one lead and this plane.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1512014 SV L PLACEINFOIC
GEM for SIPLACE V5.01
Page 176 of 252 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
Placement information for IC-head 2 Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
8;SRVLWLRQ!>PP@
8<SRVLWLRQ!>PP@
)$QJOH!>GHJUHHV@
8)RUFH,QGH[!
$5HIHUHQFH'HVLJQDWRU!
$&RPSRQHQW1DPH!
83DFNDJH)RUP1XPEHU!
83ODFHPHQW5HVXOW!
,3ODFHPHQW9DFXXP!
,9DFXXP!
8'DWD9DOLG!
,;GHYLDWLRQ!>PP@
,<GHYLDWLRQ!>PP@
)$QJOH!>GHJUHHV@
84XDOLW\!>@
8/HQJWK!>PP@
8:LGWK!>PP@
/
,3LWFKBSHUBOHDGBJURXS!

,3LWFKBSHUBOHDGBJURXS!
!
)0D[/HDG'HY!>PP@
)0D[%DOO'HY!>PP@
)2UWKR'HY!>GHJ@
8/HDG&RXQW!
!
The fields following the data item „DataVaild“
represent the result of optical centering. All fields are
not necessarily valid for all package forms. Verify the
validity of a field using the „data valid“ byte and refer to
the corresponding flag for the appropriate field.
[;GHY<GHYDQGDQJOH
[OHQJWKDQG ZLGWK
[OHDGFRXQW
[SLWFK
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 177 of 252
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
[RUWKRJRQDOGHYLDWLRQ
[PD[OHDGGHYLDWLRQ
[PD[EDOOGHYLDWLRQ
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1512015 SV L PICKUPINFOIC
Pick-up information for IC-head . Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
$&RPSRQHQW1DPH!
,7UDFN1XPEHU!
8)HHGHU7\SH!
,/HYHO!
,'LYLVLRQ!
80DFKLQH6LGH!
83LFN8S5HVXOW!
,3LFN8S9DFXXP!
,9DFXXP!
!
If the component was picked up from a feeder /HYHO
will contain -1. In the case that the component was
picked up from a tray in the waffle pack changer
7UDFN1XPEHU is set to -1. If both values are not equal
to -1 the component was picked up from a „manual
tray“.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
I / O Ports
2012001 SV U1 INPUTPORTBYTE1
Bit 0: If bit is set, the upper proximity switch of the
lifting table is not switched.
Bit 1: If bit is set, the lower proximity switch of the
lifting table is not switched.
Bit 2: If bit is set, the proximity switch of the
stopper of the parallel conveyer is switched.