GEM for SIPLACE V5.01 Page 240 of 252 ©Siemens AG, all rights reserved 2111010 FM_FLUX_CHECKSUMME Check sum error upon activation of f lux pump* 1 2111011 FM_FLUX_Z_OBEN Z-axis of flux nozzle not in raised position* 1 21…

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 239 of 252
<GANTRYINFOREV2> or
<GANTRYINFOIC> will be updated.
2010004 TrackFull Track reset to full 1
2010005 TrackEmpty Track set to empty 1
2010006 RefRunGantry1 Reference run complete for the gantry 1
axis
1
2010007 RefRunGantry2 Reference run complete for the gantry 2
axis
1
2010008 TableDownload Software downloaded to the table and
<SOFTWAREREVTABLE> will be
updated.
23
2010009 SingleCircuitOmit The machine signals that it found a single
circuit to omit (Ink Punkt)
1
2010010 TapeCutLeft Tape cut on left side of machine 1
2010011 TapeCutRight Tape cut on right side of machine 1
2010013 PCBstartProcessing Start of the placement process for the
PCB in the center conveyor
1
2010015 MachineReStarted SIPLACE station is re-booting 1
2010016 PickupError An Pickup-Error has occured and
<SEGMENT>, <COMPONENTNAME>,
<MASCHINESIDE>, <TRACKNUMBER>,
<DIVISION>, <LEVEL>, <GANTRYID>,
<GANTRYGROUPID> and <HEADID>
will be updated
28
2010017 PlaceError An Place-Error has occured and
<SEGMENT>,
<REFERENCEDESIGNATOR>,
<COMPONENTNAME>, <GANTRYID>,
<GANTRYGROUPID>, <HEADID>,
<PACKAGEFORMNUMBER> and
<PLACEERRORDESCRIPTION> will be
updated
29
)OX[
CEID Name Description
2111001 FM_FLUX_SYSFEHL Flux module: System error in SW
module*
1
2111002 FM_FLUX_WRITE_FLUXMA Flux module: Error writing FLUX.MA file* 1
2111003 FM_FLUX_READ_FLUXMA Flux module: Error reading FLUX.MA file* 1
2111004 FM_FLUX_NOT_INIT Flux pump not initialized* 1
2111005 FM_FLUX_INITIALISIEREN Error upon initialization of flux pump* 1
2111006 FM_FLUX_VALVE Faulty flux valve* 1
2111007 FM_FLUX_PLUNGER Faulty flux syringe* 1
2111008 FM_FLUX_TIMEOUT Timeout of flux pump* 1
2111009 FM_FLUX_COMMAND Incorrect command to flux pump* 1

GEM for SIPLACE V5.01
Page 240 of 252 ©Siemens AG, all rights reserved
2111010 FM_FLUX_CHECKSUMME Checksum error upon activation of flux
pump*
1
2111011 FM_FLUX_Z_OBEN Z-axis of flux nozzle not in raised
position*
1
2111012 FM_FLUX_Z_KLEMMT Z-axis of flux nozzle jammed* 1
2111013 FM_FLUX_LEER Flux tank empty* 1
2111014 FM_FLUX_NACHFUELLEN Warning: Replenish flux tank* 1
* Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these flux
collection events.

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 241 of 252
$ODUPV
There are no alarms defined for SIPLACE
$/,' $/&' $/7; 'HVFULSWLRQ 21&(,' 2))
&(,'
$/,' Alarm ID
$/&' Alarm Severity Code. The low-order 7-bits of ALCD specifies the severity
code. The high-order bit (bit-8) shows the current alarm state (1=SET,
0=CLEAR).
$/7; Alarm Text. This is the actual string sent the Host in the Alarm Report
(S5F1).
21&(,' This is the Collection Event that is signaled when the alarm state changes
from CLEAR to SET ("going-on").
2))&(,' This is the Collection Event that is signaled when the alarm state changes
from SET WRCLEAR ("going-off").