00191134-03 - 第28页
GEM for SIPLACE V5.01 Page 28 of 252 ©Siemens AG, all rights reserved 6,3/$ &(3URFHVV6WDWH7 UDQVLWLRQV # From Tr igger To Descript ion 1 Unknown Power-Up Machine Initialization At power-up, the Equipm ent d…

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 27 of 252
3URFHVV6WDWHV
The Process State Diagram illustrates in detail the processing at the SIPLACE.
Machine
Initialization
Single
Function
Processing
7
1
2
3
4
5
6
3URFHVV6WDWH'LDJUDP

GEM for SIPLACE V5.01
Page 28 of 252 ©Siemens AG, all rights reserved
6,3/$&(3URFHVV6WDWH7UDQVLWLRQV
# From Trigger To Description
1 Unknown Power-Up Machine
Initialization
At power-up, the Equipment
defaults to the 0DFKLQH
LQLWLDOL]DWLRQ state.
2 Machine
Initialization
Machine is
ready
Processing All data is available to
produce a board. All
peripheral equipment like
the Vision system is
initialized and the machine
has finished the reference
runs correctly. In this state
the machine will start its
work, when a PCB is put on
the input conveyor
3 Processing new Data form
the Host
Machine
Initialization
New production data is
send during the machine is
processing a board. The
board will be finished and
the machine will go to the
0DFKLQHLQLWLDOL]DWLRQ state
4 Machine
Initialization
a) Fatal Error
during machine
initialization
b) Stop-Button
on GUI
Single
Function
When a fatal error occurs
during machine initialization
it will automatically switch to
VLQJOHIXQFWLRQ mode.
In the case that the
operator press the Stop-
Button on the GUI, the
machine will first end the
board in the center
conveyor (if there is one)
and will then enter the
VLQJOHIXQFWLRQ mode.
5 Single
Function
Start-Button on
GUI
Machine
Initialization
When the machine is in
single function mode, the
operator press the Start-
button and the Prestate
was machine Initialization
the machine will return to
the 0DFKLQHLQLWLDOL]DWLRQ
state.
6 Processing a) Fatal Error
during machine
initialization
b) Stop-Button
on GUI
Single
Function
When a fatal error occurs
during processing the
machine will automatically
switch to VLQJOHIXQFWLRQ
mode.
In the case that the
operator press the Stop-
Button on the GUI, the
machine will first end the
board in the center
conveyor (if there is one)
and will then enter the
VLQJOHIXQFWLRQ mode.

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 29 of 252
# From Trigger To Description
7 Single
Function
Start-Button on
GUI
Processing When the machine is in
single function mode, the
operator press the Start-
button and the Prestate
was Processing the
machine will return to the
3URFHVVLQJ state.
6,3/$&(3URFHVV6WDWHV
0DFKLQH,QLWLDOL]DWLRQ
In this state, the peripheral equipment is initialized and the machine process the
necessary reference runs. The data which was downloaded from the host is split in pieces
for the different subsystem of the machine
3URFHVVLQJ
In this state, the SIPLACE is producing a board.
6LQJOHIXQFWLRQ
In this state, the Operator can teach fiducials, react on run-time-errors like empty feeders.
5HODWHG9DULDEOHV
The following table lists the variables (SV's, EC's, or DVVALS) which are relevant to the
Equipment processing states. For a more complete description of these variables, see
"Chapter 6 Variables".
Variable Name VID
PREVIOUSPROCESSSTATE 1002012
PROCESSSTATE 1002011
5HODWHG&ROOHFWLRQ(YHQWV
The following lists the collection events (CEIDs) which are relevant to the Process State.
For a more complete description of these events, see "Appendix B -- Collection Events" or
the description in this chapter.
Collection Event CEID
Init2Process 1000010
Process2Init 1000011
Process2SingleFunction 1000012
SingleFunction2Process 1000013
Init2SingleFunction 1000016
FunctionSingle2Init 1000017