00191134-03 - 第44页
GEM for SIPLACE V5.01 Page 44 of 252 ©Siemens AG, all rights reserved (UURU0HVVDJHV The SIPLACE provides standard Stream 9 m ess ages to report SECS- II errors. See 4.9 "SECS Message Detail" f or detailed…

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 43 of 252
(TXLSPHQW7HUPLQDO6HUYLFHV
The SIPLACE supports exchange of free text messages with the Host (SECS Stream 10).
This Equipment accepts the following messages from the Host, and responds accordingly
if the W-Bit is set to 1:
S10F3 /* Single Line Data */
S10F5 /* Multi-Line Data */
S10F9 /* Broadcast */
The message text will be displayed on the Equipment's CRT. Collection Event S10Ack
(CEID 1000002) occurs once the operator has acknowledged the message and an Event
Report will be sent to the Host (if enabled).
The S10F3 and S10F9 are restricted to a single TEXT data item, but S10F5 can contain
multiple TEXT data items. Each TEXT data item is limited to 160 characters. Each data
item in S10F5 will be displayed on a separate line at the equipment.
If the Operator has not acknowledged an existing message when the Host sends another
message, the new message will be displayed and the old one discarded.
The Host can send a message with a 0-length text to clear the Operator text display.
Also, the Equipment allows the operator to send a single block message to the Host via
S10F1. The maximum length of this text is 160 characters. The S10F2 response from
the Host is ignored.
5HODWHG9DULDEOHV
There are no relevant variable for the Equipment Terminal Capability.
5HODWHG&ROOHFWLRQ(YHQWV
There is one CEID related to the Equipment Terminal Capability. For a more complete
listing of these collection events, please see "Appendix B -- Collection Events".
Collection Event CEID
HostMsgAckr 1000002

GEM for SIPLACE V5.01
Page 44 of 252 ©Siemens AG, all rights reserved
(UURU0HVVDJHV
The SIPLACE provides standard Stream 9 messages to report SECS-II errors. See 4.9
"SECS Message Detail" for detailed description of these messages:
S9F1 Unrecognized Device ID
S9F3 Unrecognized Stream
S9F5 Unrecognized Function
S9F7 Invalid Data
S9F9 Transaction Timeout
S9F11 Data Too Long
5HODWHG9DULDEOHV
There are no Variables relevant for Error Messages.
5HODWHG&ROOHFWLRQ(YHQWV
There are no CEID related to Error Messages.

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 45 of 252
&ORFN
The SIPLACE contains Clock/Calendar hardware, by which it knows the current date and
time.
The Host can send S2F31 to set the Equipment's Clock/Calendar hardware.
The Host can send S2F17 to read the Equipment's Clock/Calendar hardware.
The Operator can initiate a Date/Time request from the Host. The Equipment will send
S2F17 to the Host and will set its clock according to the data in the S2F18 reply.
5HODWHG9DULDEOHV
The following table lists the variables (SV's, EC's, or DVVALS) which are relevant to
material movement. For a more complete description of these variables, see "Appendix A
-- Variables".
Variable Name VID
CLOCK 1002022
TIME 1002023
5HODWHG&ROOHFWLRQ(YHQWV
There are no CEID related to the Clock Capability.