00191134-03 - 第56页

GEM for SIPLACE V5.01 Page 56 of 252 ©Siemens AG, all rights reserved bit 8 = 1 means alarm set bit 8 = 0 means alarm cleared bit 7-1 is alarm categor y 0 = not used 1 = Personal saf ety 2 = Equipment s afety 3 = Paramet…

100%1 / 245
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 55 of 252
 'DWD,WHP'LFWLRQDU\
$%6 - Any binary string
Format : B
used in : S2F25, S2F26
$&.& - Acknowledge Code
Format: B[1]
0 = Accepted
>0 = error, not accepted
1 - 63 reserved
used in : S5F2, S5F73
$&.& - Acknowledge Code
Format: B[1]
0 = Accepted
>0 = error, not accepted
1 - 63 reserved
used in : S6F2, S6F3, S6F10, S6F12, S6F14
$&.& - Acknowledge Code
Format: B[1]
0 = Accepted
1 = Permission not granted
2 = Length error
3 = Matrix overflow
4 = PPID not found
5 = Mode unsupported
6 = busy
7 = Control state is not „remote“
8 = Control mode is not „GEM-Host“
9 = recipe type is not binary
10 - 63 reserved
used in : S7F4, S7F18
$&.& - Acknowledge Code
Format: B[1]
0 = Accepted for display
1 = Message will not be displayed
2 = Terminal not available
3 = Message to long (more than 160 char)
4 - 63 reserved
used in : S10F2, S10F4, S10F6, S10F10
$/&' - Alarm code byte
Format: B[1]
GEM for SIPLACE V5.01
Page 56 of 252 ©Siemens AG, all rights reserved
bit 8 = 1 means alarm set
bit 8 = 0 means alarm cleared
bit 7-1 is alarm category
0 = not used
1 = Personal safety
2 = Equipment safety
3 = Parameter control warning
4 = Parameter control error
5 = Irrecoverable error
6 = Equipment status warning
7 = Attention flags
8 = Data integrity
>8 = Other categories
9 - 63 reserved
used in: S5F1, S5F6, S5F8
$/(' - Alarm enable/disable code
Format: B[1]
bit 8 = 1 means enable alarm
bit 8 = 0 means disable alarm
used in: S5F2, S5F4
$/,' - Alarm identification
Format: U4
used in: S5F1 S5F2 S5F5, S5F6, S5F8, S5F71, S5F73
$/3< - Alarm priority
Format: U1
used in: S5F71
$/7; - Alarm text
Format: A[40]
used in: S5F1 S5F6, S5F8
$QJOH - Angle
Format: F8
Angles are measured counterclockwise from the positive X-axis to the positive Y-axis
Units are 1/100 degree.
used in : PLACEINFOREV1, PLACEINFOREV2
$6(5 - Alarm serial number
Format: U4
used in: S5F71
$67$7 - Alarm status
Format: Boolean
used in: S5F71, S5F73
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 57 of 252
&((' - Collection event enable/disable code
Format: B[1]
False = Disable
True = Enable
&(,' - Collection event ID
Format: U4
used in: S2F35, S2F37, S6F3, S6F9, S6F11, S6F13, S6F15, S6F16, S6F17, S6F18
&/2&. - Clock YYYYMMDDhhmsscc
Format A[16]
used in: S5F71, S5F73, CLOCK, PICKUPDATARESETPOINT
FORVHGBQR]]OH Vacuum value for a nozzle
vacuum value measured with closed nozzle
Format: I4
Units are mbar
used in : VACUUMDATAREV1, VACUUMDATAREV2, VACUUMDATAIC
&0'$ - Command acknowledge code
Format: B[1]
0 = completed or done
1 = command does not exist
2 = cannot perform now
>2 = other equipment specific error
3- 63 reserved
used in: S2F22, S2F28
&RPS&RXQW Number of components per tray in the waffle pack changer
Format: I2
used in : INVENTARYWPC
&RPS/HIW3ODFH Number of components left to be placed on the actual PCB
Format: I2
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC
&RPS3LFNHG8S Number of components which were picked up successfully since the
current PCB reached the center conveyor
Format: I2
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC
&RPS3ODFHG Number of components which were placed since the current PCB
reached the center conveyor
Format:U4
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC
&RPSRQHQW1DPH - Name of a component
Format: A