00191134-03 - 第71页
GEM for SIPLACE V5.01 ©Siemens AG, all rights r eserved page 71 of 252 For com patibility wi th older Host im plem entations, the Equipm ent allows the following alternative form f or this m ess age using an array form a…

GEM for SIPLACE V5.01
Page 70 of 252 ©Siemens AG, all rights reserved
6WUHDP
6)$UH<RX7KHUH
S1F1 W. * H<->E
The Host may send this message to the Equipment at any time.
The SIPLACE sends this message periodically as a "heartbeat" to determine if the SECS
link is operational.
The Equipment Constant ConfigConnect can be set to cause the Equipment to send
S1F1 instead of S1F13 for Connect Request.
6)2Q/LQH'DWD(TXLSPHQWWR+RVW
S1F2 * H<-E
<L
<A MDLN> * MDLN Model Number
<A SOFTREV> * SOFTREV Software Revision
> .
The Equipment reports its Model Number and Software Revision.
6)2Q/LQH'DWD+RVWWR(TXLSPHQW
S1F2 * H->E
<L> .
6)6HOHFWHG6WDWXV5HTXHVW
S1F3 W * H-> E
<L
<U4 VID> * Variable ID
...
> .
The Host requests status from the SIPLACE. The Host sends the VIDs of interest.
Several VIDs can be specified if desired.
Normally, only VIDs of class SV (i.e. Status Variables) are used in this message.
However, the SIPLACE allows the Host to use any VID of class DV, EC, or SV.
If S1F3 contains a zero-length list, then the SIPLACE will report all variables of class SV,
in order by VID.

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 71 of 252
For compatibility with older Host implementations, the Equipment allows the following
alternative form for this message using an array format:
S1F4 W * H->E
<U4 VID...>.
6)6HOHFWHG6WDWXV'DWD
S1F4 W * H<-E
<L
<V> * Status Variable Value
...
> .
The Equipment returns the Variable Values in the order requested by S1F3. If any VID
specified in S1F3 is invalid, the corresponding V in S1F4 has the following error format:
<L> * V for Invalid VID
6)6WDWXV9DULDEOH1DPHOLVW5HTXHVW
S1F11 W * H->E
<L
<U4 VID> * Status Variable ID
...
>.
The Host format descriptions for the specified Variables. Several VIDs can be specified if
desired.
Normally, only VIDs of class SV (i.e. Status Variables) are used in this message.
However, any VID of class DV, EC, or SV can be used.
If S1F11 contains a zero-length list, then the Equipment will report all variables of class
SV, in order by VID.
S1F11 W * H->E
<L> .

GEM for SIPLACE V5.01
Page 72 of 252 ©Siemens AG, all rights reserved
6)6WDWXV9DULDEOH1DPHOLVW5HSO\
S1F12 * H<-E
<L
<L [3]
<U4 VID> * Variable ID
<A SVNAME> * Status Variable Name
<A UNITS> * Units of Measure
...
> .
The Equipment returns the Variable descriptions in order requested in S1F11. If any VID
specified in S1F11 is invalid, the corresponding List in S1F12 has the following error
format:
<L> * Instead of L [3]
6)&RQQHFW5HTXHVW
The Equipment sends this message using the following format.
S1F13 W * H<-E
<L
<A MDLN>
<A SOFTREV>
> .
The Host sends this message using the following format.
S1F13 W * H->E
<L> .
Either end of the link may send S1F13 as the first message to establish connection of the
link.
Under the SIPLACE's initialization logic, the Equipment will always attempt to establish the
link. If no Host acceptance reply is received, the Equipment sends this message
periodically.