GEM for SIPLACE V5.01 Page 8 of 252 ©Siemens AG, all rights reserved 5.5.1 Unform atted, Host-Initiated ........................................................................150 5.5.2 Unform atted, Host-Initiated .....…

100%1 / 245
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 7 of 252
4.15 STREAM 13.........................................................................................................133
4.16 S
TREAM 14.........................................................................................................134
6(&66&(1$5,26  
5.1 E
QUIPMENT COMMUNICATIONS............................................................................135
5.1.1 Equipment Establishes Communications ..................................................135
5.1.2 Host Establishes Communications............................................................136
5.1.3 Simultaneous Establish .............................................................................136
5.1.4 Losing Connection, Re-Connecting...........................................................137
5.1.5 Heartbeat...................................................................................................137
5.2 D
ATA COLLECTION..............................................................................................138
5.2.1 Host Initializes Event..................................................................................138
5.2.2 Equipment Reports Event..........................................................................139
5.2.3 Equipment Reports Annotated...................................................................140
5.2.4 Host Initiates Trace....................................................................................141
5.2.5 Host Terminates Trace..............................................................................142
5.2.6 Host Requests Status................................................................................142
5.2.7 Host Defines Limits....................................................................................142
5.2.8 Host Queries Defined Limits......................................................................142
5.2.9 Host Requests Report by CEID.................................................................143
5.2.10 Host Requests Annotated Report by CEID................................................143
5.2.11 Host Requests Report by RPTID...............................................................143
5.2.12 Host Requests Annotated Report by RPTID .............................................143
5.2.13 Are You There ...........................................................................................143
5.2.14 Host Reads Equipment..............................................................................144
5.2.15 Host Sets Equipment Constants................................................................144
5.3 A
LARMS..............................................................................................................145
5.3.1 Equipment Reports Alarm..........................................................................145
5.3.2 Host Enables/Disables Alarms ..................................................................145
5.3.3 Host Requests Alarms...............................................................................145
5.3.4 Alarm Report (GEM, Ver 3.1 Compatibility)...............................................146
5.3.5 Alarm Report (GEM, Ver 1.7 Compatibility)...............................................146
5.4 C
ONTROL STATE.................................................................................................147
5.4.1 Host Sends On-Line Command.................................................................147
5.4.2 Host Sends Off-Line Command.................................................................147
5.4.3 Host Sends Remote Command.................................................................147
5.4.4 Equipment Rejects Host Command ..........................................................147
5.4.5 Go Remote, Operator-Initiated ..................................................................148
5.4.6 Go Local, Operator-Initiated ......................................................................148
5.4.7 Operator Command, Successful ...............................................................149
5.5 P
ROCESS PROGRAM ...........................................................................................150
GEM for SIPLACE V5.01
Page 8 of 252 ©Siemens AG, all rights reserved
5.5.1 Unformatted, Host-Initiated ........................................................................150
5.5.2 Unformatted, Host-Initiated ........................................................................150
5.5.3 Unformatted, Equipment-Initiated ..............................................................150
5.5.4 Unformatted, Equipment-Initiated ..............................................................151
5.5.5 Host Deletes Process.................................................................................151
5.5.6 Host Requests Directory ............................................................................151
5.5.7 Operator Changes Process Program Library.............................................152
5.6 E
QUIPMENT TERMINAL COMMUNICATIONS.............................................................153
5.6.1 Host to Equipment, Single Line..................................................................153
5.6.2 Host to Equipment, Multi-Line....................................................................153
5.6.3 Equipment Sends Text to Host ..................................................................153
5.7 E
RROR MESSAGES..............................................................................................154
5.7.1 Unrecognized Device ID.............................................................................154
5.7.2 Unrecognized Stream.................................................................................154
5.7.3 Unrecognized Function ..............................................................................154
5.7.4 Illegal Data Format.....................................................................................154
5.7.5 Data Too Long............................................................................................155
5.8 C
LOCK ................................................................................................................156
5.8.1 Host Sets Date and Time...........................................................................156
5.8.2 Host Requests Date and Time...................................................................156
5.8.3 Equipment Requests Date and Time.........................................................156
5.9 S
POOLING...........................................................................................................157
5.9.1 Host Enables Spooling of Messages..........................................................157
5.9.2 Messages Spooled and Transmitted..........................................................158
5.9.3 Host Purges Spool .....................................................................................159
9$5,$%/(6 
35('(),1('5(32576 
&2//(&7,21(9(176
$/$506
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 9 of 252
 ,QWURGXFWLRQ
This document describes the SECS interface version 405.xx provided on the SIPLACE.
Changes from Host Interface Manual V2.0:
Section 4.2: Documentation of Data Items corrected: PickUpResult, PlacementResult
Section 4.9: Documentation corrected: PPBODY is a binary data block
Section 6: Documentation corrected: PICKUPERRORS (VID 2012019)
Section 8: New Collection Events: PCBstartProcessing (CEID 2010013),
MachineReStarted (CEID 2010015)
Changes from Host Interface Manual V3.01:
Section 4.2: Documentation of Data Items corrected.
Section 6: New Variables: COMPONENTBARCODE (VID 912003),
WAYOFINPUTCOMPONENTBARCODE (VID 912004), MACHINESIDE (VID
2012022), TRACKNUMBER (VID 2012023), DIVISION (VID 2012024), LEVEL (VID
2012025), SEGMENT (VID 2012026), COMPONENTNAME (VID 2012027),
GANTRYID (VID 2012028), GROUPGANTRYID (VID 2012029), HEADID (VID
2012030), REFERENCEDESIGNATOR (VID 2012031), PACKAGEFORMNUMBER
(VID 2012032), PLACEERRORDESCPIPTION (VID 2012033),
GEMTIMEFORMAT(VID 1002065)
Variable TIME (VID 1002023) changed
Section 6: Documentation corrected: PLACEINFOREV1 (VID 1312004),
PLACEINFOREV2 (VID 1412003), PLACEINFOIC (VID 1512014) and oder of VID’s
corrected.
Section 7: New Predefined Reports: BeBarcode(RPTID 27), PickUpError (RPTID 28),
PlaceError (RPTID 29)
Section 8: New Collection Event: ComponentBCread (CEID 920002), PickUpError
(CEID 2010016), PlaceError (CEID 2010017)
Changes from Host Interface Manual V3.02:
Section 3.1.9: Description of Control State (Online/Local) completed
Section 4.2: Documentation of Data Items corrected.
Section 6: Order of the Variables corrected. New Variables:
PCBSIDEININPUTCONVEYOR(VID 912005), PCBSIDEINCENTERCONVEYOR
(VID 912006), BCINTWINCENTERCONVEYOR (VID 912011),
BCINTWININPUTCONVEYOR (VID 912012), PCBSIDEINTWININPUTCONVEYOR
(VID 912015), PCBSIDEINTWINCENTERCONVEYOR (VID 912016),
BCREADEREXIST (VID 912017), SOFTWAREREVGEM (VID 1002067)
Description of HEIGHTREVOLVER1 (VID 1312001) and HEIGHTREVOLVER2 (VID
1412001) changed
Names of Variables corrected: TRANSPORTWIDTH, GANTRYONERROR
(correction in manual)
GUINOZZLETYPE VID corrected to 11220006 (correction in manual)
STIME format corrected in this manual: S6F1 description
Section 7:
Predefined Reports expanded: Nozzle1(RPTID 14), Nozzle2 (RPTID 15)
Predefined Reports deleted: RefRunHead1(RPTID 19), RefRunHead2 (RPTID 20)
New Predefined Reports: BarcodeTwin (RPTID 30)
Section 8: New Collection Event: BCTwinRead (CEID 920011)