N7201A653E - 第115页

NPM- TT2 EJ M1EE-MB-04M-0 0 1 4-1-1 -2 2 2 Checking the vacuum pump supply pressure 1 + 3 ● Pressure range: -100 to -87 kPa (The indicator color changes from gray to light blue, and the vacuum pump is activated) Check th…

100%1 / 502
NPM-TT2 EJM1EE-MB-04M-00
Before
opera-
tion
Inspecting the
pressure gauge 1
Tool used: None Time required: 3 minutes (Machine power ON)
4-1-1-1
Maintenance
4-1-1
Check the air pressure
Front side
Rear side
Main air pressure
(0.500 to 0.505 MPa)
Describes inspection of the supply pressure.
Vacuumbreakpressure
(8 to12 kPa)
Vacuum pump supply
pressure(-100 to -87 kPa)
Clean blow pressure
(0.13 to 0.14 MPa)
Option air pressure
(0.4 MPa)
NPM-TT2 EJM1EE-MB-04M-00
1
4-1-1-2
2
2
Checking the vacuum pump supply pressure
1
+
3
Pressure range: -100 to -87 kPa
(The indicator color changes from gray
to light blue, and the vacuum pump is
activated)
Check the vacuum pump supply
pressure (the pressure gauge)
Every
24
hours
PeriodicPeriodic
inspection
NPM-TT2 EJM1EE-MB-04M-00
Before
opera-
tion
Rear side
4-1-1-3
Maintenance
4-1-1
Check the air pressure (Main air pressure)
Tool used: Allen wrench (3 mm) Time required: 3 minutes
Adjust when the main air pressure is out of the required value range.
Inspecting the
pressure gauge 2
1
Remove the screws and remove
the rear pressure gauge cover
2
Adjust the pressure to be
within the range
Main air
regulator knob
How to operate the regulator knob
1: Pull the knob up
2: Adjust it
3: Pull it down
3
Attach the rear pressure
gauge cover
Screw: Three locations
Screw: Three
locations
Remove screws
Rear
pressure
gauge cover