N7201A653E - 第118页

NPM- TT2 EJM1EE-MB-04 M-00 4-1-1 -5 Adjusting the air pressure (pressure of cleaning blow , Option air pressure and vacuum break ) Tool used: Phillips sc rewdriver (No.2) , spanner (10 mm) Time required: 20 minutes ● If …

100%1 / 502
NPM-TT2 EJM1EE-MB-04M-00
4-1-1-4
Every
24
hours
PeriodicPeriodic
inspection
NPM-TT2 EJM1EE-MB-04M-00
4-1-1-5
Adjusting the air pressure (pressure of cleaning blow , Option air pressure and vacuum break )
Tool used: Phillips screwdriver (No.2), spanner (10 mm) Time required: 20 minutes
If cleaning blow pressure, Option air pressure and vacuum break pressure are out of prescribed value,
adjust them.
Before
opera-
tion
Maintenance
4-1-1
Inspecting the
pressure gauge 3
1
Adjust the pressure to be
within the range
4
Regulator knob
Cleaning blow regulator
knob
How to use the regulator knob
1: Pull the knob up
2: Adjust it
3: Pull it down
(For cleaning blow pressure)
Vacuum break
pressure regulator
knob
Lock nut
When the vacuum break regulator
is adjusted, loosen the lock nut.
After adjusted, tighten the nut.
Detach the tray
feeder or the
feeder cart
For a tray feeder
( P.14-8)
For a feeder cart
( P.3-2)
Cleanblowpressure
(0.13 to 0.14 MPa)
Optionairpressure
(0.4MPa)
Vacuum break
pressure
(8 to 12 kPa)
NPM-TT2 EJM1EE-MB-04M-00
Front side
Remove the cover
inside of the cart
Image as seen from the
arrow direction
2
4-1-1-6
Screw: Four locations
Remove screws
Cover
3
Turn ON the
main power
switch
5
Attach the cover in
the main unit
6
Attach the tray
feeder or the
feeder cart
Front side
Cover
For a tray feeder
( P.14-8)
For a feeder cart
( P.3-2)
Every
24
hours
PeriodicPeriodic
inspection
ON