N7201A653E - 第235页

10 Periodic inspection Every-18000-hours

100%1 / 502
NPM-TT2 EJM1EE-MB-09M-01
Inspecting the 1006
nozzle
(option)
Maintenance
9-3
Tool used: None Time required: 1 minute
Clamp groove
9-3
Confirm whether clamp grooves wear out or not.
(To prevent from decreasing clamping force after long time use)
Replace it after 6000 hours (a year) or 700000 times of automatic nozzle changer of operation. It is
recommended that you stock spare nozzles.
10 Periodic inspection
Every-18000-hours
NPM-TT2 EJM1EE-MB-10M-00
4
When there is no
damage or wear out
Inspecting the nozzle
holder
(option)
10-1-1
Maintenance
10-1
Tool used: None
Time required: 10 minutes (per head)
7
Attach the spring for nozzle cushion
(For 8-nozzle head)
5
Attach the spring
for holding
clamp claws
6
Check that the claws are
securely engaged in the
grooves in the nozzle
holder.
Push in the
clamp claw
1
Remove the spring for nozzle cushion
2
3
Pull out the
clamp claws
Remove the
spring for holding
clamp claws
Spring for
nozzle
cushion
Clamp claws
Spring for
holding
clamp claws
8-nozzle head
Spring for
holding
clamp claws
Check the
component, and
if any damage or
wear out is
found, replace it
Clean it and apply
grease (P.6-3)
For 8-nozzle head
Twist the spring to remove.
If any part wears out, it may cause pickup error or placement error. So , please inspect them after using
about 18000 hours. If any part wears out, replace it. We recommend replacing all parts at the same time.
Groove in