NPM- TT2 EJ M1EE-MB-13M-0 2 + 1 Plane calibratio n XY Plane calibr a tion XY (PC size conveyor) 1 Explains the method for calibrating the plane calibration XY. This operation procedur e is also shared by the 8- and 3-noz…

100%1 / 502
NPM-TT2 EJM1EE-MB-13M-02
13-2-2
Confirm the message
6
6
When you do not save the data
To cancel
(The screen remains as it is in . )
5
Confirm the message
7
(XY unit moves to the origin)
+
7
Confirm that it has been
successfully completed
4
5
Perform steps to for the
other table.
1
4
Calibration
4 5
NPM-TT2 EJM1EE-MB-13M-02
+
1
Plane
calibratio
n XY
Plane calibration XY
(PC size conveyor) 1
Explains the method for calibrating the plane calibration XY.
This operation procedure is also shared by the 8- and 3-nozzle heads.
Place the plane calibration jig on the transfer conveyor to the left or right of the machine by hand and
operate it. (Two plane calibration jigs: N210141055AB)
Perform calibration on lane 1 and 2 at once.
Do not turn OFF the power of the machine during calibration.
Remove all the PCB support pins before performing plane calibration.
If you cannot set a plane calibration jig, manually load the PCB from the pre-process machine and set the
jig using the workbench (please prepare yourself).
Check that there are no PCBs
present inside the machine
If ‘error’ message appears, remove all
the PCBs remaining inside the machine,
and try again.
1
(The width is adjusted)
(The head moves to the retraction
position.)
Maintenance
13-3-1
2
Prepare for the first plane
calibration XY
4
3
Open the safety cover
Servo switch OFF
13-3-1-1
NPM-TT2 EJM1EE-MB-13M-02
5
Set the plane calibration jig
Manually move the calibration jig and
align the left end of the plane
calibration jig to the left side guide line
on the PCB conveyor upper surface.
(Both on lane 1 and 2. Common in
each PCB flow direction)
Set the reference mark on the plane
calibration jig to the reference rail.
Attach the plane calibration jig to the
reference rail.
Calibration
6
Close the safety cover
7
Servo switch ON
+
8
8
If you cannot set a plane calibration jig,
manually load the PCB from the pre-
process machine and set the jig using
the workbench (please prepare
yourself).
Operator
Guide line
Reference mark
Reference mark
Reference rail
Reference rail
Lane 1
Lane 2
Plane
calibration jig
13-3-1-2
You can also remove the feeder cart
and set a plane calibration jig.