N7201A653E - 第317页

NPM- TT2 EJM1EE-MB-13 M-02 Calibration 13-3-1 -6

100%1 / 502
NPM-TT2 EJM1EE-MB-13M-02
Plane
calibratio
n XY
18
Prepare for removing the plane
calibration jig
Maintenance
13-3-1
Open the safety cover
19
20
Push the plane calibration jig
out of the machine by hand
through the left-hand or right-
hand transfer conveyor.
21
22
Close the safety cover
23
24
24
(Completes plane calibration XY
operation)
Confirm the message
To cancel
(The screen remains as it is
in )
16
Servo switch OFF
Servo switch ON
13-3-1-5
Plane calibration XY
(PC size conveyor) 3
NPM-TT2 EJM1EE-MB-13M-02
Calibration
13-3-1-6
NPM-TT2 EJM1EE-MB-13M-02
+
1
Plane
calibratio
n XY
Plane calibration XY
(M size conveyor) 1
Explains the method for calibrating the plane calibration XY.
This operation procedure is also shared by the 8- and 3-nozzle heads.
Place the plane calibration jig on the transfer conveyor to the left or right of the machine by hand and
operate it. (One plane calibration jigs: N210147296AC)
Do not turn OFF the power of the machine during calibration.
Remove all the PCB support pins before performing plane calibration.
If you cannot set a plane calibration jig, manually load the PCB from the pre-process machine and set the
jig using the workbench (please prepare yourself).
Check that there are no PCBs
present inside the machine
If ‘error’ message appears, remove all
the PCBs remaining inside the machine,
and try again.
1
(The width is adjusted)
(The head moves to the retraction
position.)
Maintenance
13-3-2
2
Prepare for the first plane
calibration XY
4
3
Open the safety cover
Servo switch OFF
13-3-2-1