N7201A653E - 第317页
NPM- TT2 EJM1EE-MB-13 M-02 Calibration 13-3-1 -6

NPM-TT2 EJM1EE-MB-13M-02
Plane
calibratio
n XY
18
Prepare for removing the plane
calibration jig
Maintenance
13-3-1
Open the safety cover
19
20
Push the plane calibration jig
out of the machine by hand
through the left-hand or right-
hand transfer conveyor.
21
22
Close the safety cover
23
24
24
(Completes plane calibration XY
operation)
Confirm the message
●To cancel
(The screen remains as it is
in )
16
Servo switch OFF
Servo switch ON
13-3-1-5
Plane calibration XY
(PC size conveyor) 3

NPM-TT2 EJM1EE-MB-13M-02
Calibration
13-3-1-6

NPM-TT2 EJM1EE-MB-13M-02
+
1
Plane
calibratio
n XY
Plane calibration XY
(M size conveyor) 1
Explains the method for calibrating the plane calibration XY.
This operation procedure is also shared by the 8- and 3-nozzle heads.
●Place the plane calibration jig on the transfer conveyor to the left or right of the machine by hand and
operate it. (One plane calibration jigs: N210147296AC)
●Do not turn OFF the power of the machine during calibration.
●Remove all the PCB support pins before performing plane calibration.
●If you cannot set a plane calibration jig, manually load the PCB from the pre-process machine and set the
jig using the workbench (please prepare yourself).
Check that there are no PCBs
present inside the machine
●If ‘error’ message appears, remove all
the PCBs remaining inside the machine,
and try again.
1
(The width is adjusted)
(The head moves to the retraction
position.)
Maintenance
13-3-2
2
Prepare for the first plane
calibration XY
4
3
Open the safety cover
Servo switch OFF
13-3-2-1