N7201A653E - 第357页

NPM- TT2 EJ M1EE-MB-13M-0 2 13-8-2 -4 Confirm the display value Put a 100 g w eight on the load cell (The value is displayed, and the lamp flashes) (The input value 1 is set) (Teaching is complete and then the lamp chang…

100%1 / 502
NPM-TT2 EJM1EE-MB-13M-02
Place-
ment
load
1
2
3
13-8-2-3
Maintenance
13-8-2
Calibration method 1
You do not need to set the value because it is already initialized before shipment.
Please calibrate the jig or the load cell after you replace it. Also, it is recommended that you calibrate it
every year.
Turn ON the power
Hold down
for at least three seconds
Confirm the input range
If the screen display differs
Choose it with
4
5
Confirm the power-supply
frequency
6
(The input range is set)
(The power-supply frequency is set)
(The screen display flashes)
If the screen display differs
(The screen display flashes)
Choose it with
3
5
34
6
2
How to use placement
load measurement jig
(option)2
NPM-TT2 EJM1EE-MB-13M-02
13-8-2-4
Confirm the display value
Put a 100 g weight on the load
cell
(The value is displayed, and the lamp
flashes)
(The input value 1 is set)
(Teaching is complete and then the lamp
changes from flashing to illumination)
Confirm that the display value
becomes stable
(The display value 1 is set)
If the screen display differs
(The display flashes)
Choose it with
8
9810
9
11
1112
10
11
7
8
9
12
Calibration
NPM-TT2 EJM1EE-MB-13M-02
Place-
ment
load
Maintenance
13-8-2
Put a 1 kg weight on the load
cell
(The value is displayed, and the lamp
flashes)
(Teaching is complete and then the lamp
changes from flashing to illumination)
Confirm that the display value
becomes stable
(The input value 2 is set)
Confirm the display value
(The display value 2 is set)
If the screen display differs
(The display flashes)
Choose it with
14
151410
15
17
1718
13
14
15
16
17
18
Calibration method 2
13-8-2-5
How to use placement
load measurement jig
(option)3