N7201A653E - 第79页
NPM- TT2 EJM1EE-MB-02 M-01 2-1-2 -6 Every-18000-hours (every 3 year s) inspection items ■ T ypes in common ■ 8-nozzle head (Option) ■ 3-nozzle head (Option) No. Unit Check and greasing location Power Check and greasing p…

NPM-TT2 EJM1EE-MB-02M-01
Every-3000-hours (every 6 months) inspection items
2-1-2-5
■ Types in common
Overview
Periodic inspection
items by cycle 3
Maintenance
2-1-2
No. Unit Check and greasing location Power
Check and
greasing points
Time
[min]
Ref.
1 Main controller Filter OFF Cleaning 20 8-1
Inspection time (min) = 20
■LNB (option)
No. Unit Check and greasing location Power
Check and
greasing points
Time
[min]
Ref.
1 FA computer Filter OFF Cleaning 5 8-2
Inspection time (min) = 5
■ 8-nozzle head (option)
No. Unit Check and greasing location Power
Check and
greasing points
Time
[min
]
Ref.
1
Nozzle holder
(per head)
Spring for nozzle cushion
OFF Cleaning 30
7-1
Inner and outer circumferences
Spring for holding clamp claws
Clamp claw
Filter
Taper surface
Nozzle-holder shaft
Nozzle holder slicing surface OFF
Cleaning
84
Grease dispensing
(FL100)
Inspection time (min) = 114 x (the number of heads)
Every-1000-hours (every two months) inspection items

NPM-TT2 EJM1EE-MB-02M-01
2-1-2-6
Every-18000-hours (every 3 years) inspection items
■ Types in common
■ 8-nozzle head (Option)
■ 3-nozzle head (Option)
No. Unit Check and greasing location Power
Check and
greasing points
Time
[min]
Ref.
1 XY unit Cable bearer OFF Check 5 10-2
No. Unit Check and greasing location Power
Check and
greasing points
Time
[min]
Ref.
1
Nozzle holder
(per head)
Clamp claw
OFF Check 10 10-1Spring for holding clamp claws
Spring for nozzle cushion
No. Unit Check and greasing location Power
Check and
greasing points
Time
[min]
Ref.
1
Nozzle holder
(per head)
Clamp claw
OFF Check 10 10-1
Spring for holding clamp claws
Inspection time (min) = 5
Inspection time (min) = 10 x (the number of heads)
Inspection time (min) = 10 x (the number of heads)
Overview
Every-6000-hours (yearly) inspection items
■ 3-nozzle head (Option)
■ Types in common
No. Unit Check and greasing location Power
Check and
greasing points
Time
[min]
Ref.
1 Touchscreen
Backlight
ON
Check 2 9-1
Hinge (Front and rear sides)
Grease dispensing
(TOUCH LUBE)
59-2
No. Unit Check and greasing location Power
Check and
greasing points
Time
[min]
Ref.
1 Nozzle 1006 nozzle OFF Check 1 9-3
Inspection time (min) = 7
Inspection time (min) = 1 x (the number of nozzles)

NPM-TT2 EJM1EE-MB-02M-01
Overview
Periodic inspection
items by unit 1
No. Unit name
Check and greasing
location
Check and
grease
points
Cycle [h]
Ref.
24 140 560 1000 3000 6000 18000
1
Main body
unit
Main air pressure
(Pressure gauge)
Air
pressure
check
○
4-1-1
Vacuum pump supply
pressure
(Pressure gauge)
○
Vacuum break pressure
(Pressure gauge)
○
Clean blow pressure
(Pressure gauge)
○
Components-ejection box
Cleaning
○
4-2-1
Vacuum pump filter
○
6-7
Emergency stop switch
Check
○
6-8
Tray connection safety
switch
○
6-8
Air drain (Regulator)
○
6-16
2 XY unit
X-,Y- axis linear guide
Apply
grease
○
6-2
X-,Y- axis Cable bearer Cleaning
○
6-20
X-,Y- axis Cable bearer Check
○
10-2
3
PCB
conveyor
PCB-support blocks Cleaning
○
5-3
Linear guide
Grease
dispensing
○
6-1
Ball spline
○
6-1
Width-adjustment ball
screw
Apply
grease
○
6-1
PCB transfer belt Check
○
6-5
PCB detection sensor Cleaning
○
6-9
4 Cover
Safety switch Check
○
6-8
Safety cover Cleaning
○
6-15
5
Touchscree
n
Color touchscreen face Cleaning
○
5-1
Backlight Check
○
9-1
Hinge
Grease
dispensing
○
9-2
6
Multi-
recognition
camera
Cover glass Cleaning
○
5-4
7
Main
controller
Filter Cleaning
○
8-1
8
13-slot
feeder
Inside of the
used-tape box
Cleaning
○
4-2-2
Feeder table
○
5-5
Cutting unit
Apply
grease
○
6-17
Connector Check
○
5-7
2-1-3-1
Maintenance
2-1-3
The lists below show check and grease locations, information, and cycles organized by unit.
■ Types in common