MAN00000772_SI-G200BB_SVCPDFA - 第102页
Install Tray Unit (Including machine modification) SHEET 63/73 WKGB-10104-03 Installing Tray Unit (Including machine modification) [Checking VU, VL clo sest reaching dist ance] 1 Return the unit to the origin. 2 Move the…

Install Tray Unit (Including machine modification)
SHEET
62/73
WKGB-10104-03
Installing Tray Unit
(Including machine modification)
[Adjustment of path line sensor]
1 Remove front cover of tray unit.
2 Store the tray pallet into the Z501.
3 Move the VU axis to the Z501 by manual
operation.
4 Adjust sensor position, and check that it is
turned ON in the presence of tray pallet and
turned OFF in the absence of tray pallet.
5 Install the removed cover to the previous
state.
There is a palette :Light
There is not palette :Dark
I/O screen of Manual mode (Input 21,20 TI)

Install Tray Unit (Including machine modification)
SHEET
63/73
WKGB-10104-03
Installing Tray Unit
(Including machine modification)
[Checking VU, VL closest reaching distance]
1 Return the unit to the origin.
2 Move the VU axis to the Z501 by manual V
axis operation.
3 Open the tray unit side cover.
4 Check that interval between the VU rack and
the VL rack is 41[mm] or more.
NOTE:
If this clearance is less than 41[mm], the relation of the
height between mounter and tray unit might be wrong.
In this case please set up again this height relation.
5 Install the removed side cover to the
previous state.
41[mm] or more
204±2[mm]

Install Tray Unit (Including machine modification)
SHEET
64/73
WKGB-10104-03
Installing Tray Unit
(Including machine modification)
[Setup of VU, VL axis parts replacement standby height]
1 Return the unit to the origin.
2 Press the Parts replace button on the
AUTO/PARTS SUPPLY STATUS screen.
3 Select the R (Tray upper) button.
4 Open the tray upper door.