Set-up HLGB-10206-01 F Ax is Setup SHEET 5/5 5. Click in an order of A XIS MOTION tab  F b u tt o n . FF Axis screen is displayed. 6. Place a check in “Norma l Cassette” and “Down” and press the [ST ART] button on the o…

100%1 / 712
Set-up
HLGB-10206-01
F Axis Setup
SHEET
4/5
7 Click the servo ON button on the F Axis
Home screen.
Servos for all axes are tuned on.
8 Click the Save button.
Height of the F axis is saved, and the F Axis Home
screen closes.
9 Change the thickness gauge to 0.2mm, and
check that it is not inserted into a gap
between the feed roller and the part feed
height jig.
10 Close the Machine Setup screen and
Calibration Menu screen.
11 Press the [ORG] button on the operation
panel to perform origin position return.
12 Check the set F axis height.
1. Click in an order of MANUAL menu
CASS. tab.
2. Input “120” into the cassette position
space, and click the Move.
3. Press the [START] button on the
operation panel.
The head moves to No.120 cassette position.
4. Replace the parts feed height jig
(110.4mm) on the feed adjustment jig
with a parts feed height jig of 86.5mm.
Feed adjusting jig
Part feed height jig
(86.5 mm)
Set-up
HLGB-10206-01
F Axis Setup
SHEET
5/5
5. Click in an order of AXIS MOTION
tabF button.
FF Axis screen is displayed.
6. Place a check in “Normal Cassette”
and “Down” and press the [START]
button on the operation panel.
The feed roller lowers.
7. Check that clearance between the
parts feed height jig (86.5mm) and the
feed roller is in a range of 0<0.2mm
with a thickness gauge.
8. After checking, place a check in the
“Up” on the FF axis careen, and press
the [START] button.
13 Also check the height of the F axis on the rear side by the same procedure as in the procedure 12.
Feed roller
Feed roller
Thickness gauge
Set-up
HLGB-10207-01
RN Axis Origin Offset Setup
SHEET
1/4
RN Axis Origin Offset Setup
Perform this working on both heads on the front side and rear side.
[Procedure]
1 Set the RN offset to “0”.
1. Click in an order of M/C SETUP menu
ORG OFFSET tabChange Offset
button.
Change Offset screen is displayed.
2. Input “0” in the RN Offset box, and
click the Set button.
RN offset value is set to “0”.