MAN00000772_SI-G200BB_SVCPDFA - 第202页
Calibration HLGB-10301-01 PWB Camera Light Calibration SHEET 1/3 PWB Camera Light Calibration Perform this working on both heads on the front sid e and rear side. [Necessary jigs] • Calibration p late jig • Jig posit ion…

Set-up
HLGB-10208-01
Pickup Check Camera Setup
SHEET
5/5
[Lateral alignment]
1 Click the ↓ Check button on the origin
offset screen to lower the Pickup check
camera.
2 Visually check that top end of the nozzle is
displayed on the center of the HEIGHT
DISPLAY screen.
3 Unless top end of the nozzle is on the center
of the window, loosen cap screws (2-CP4x8)
to adjust installing position of the check
camera.
Fix the Pickup check camera with pressing it
against upward.
4 Setup of the Pickup check camera is
completed.
1. Press the [ORG] button on the
operation panel to perform origin
position return.
2. Remove the length reference nozzle jig
from the turret No.1.
Cap screw
Press-against
location
Pickup check
camera

Calibration
HLGB-10301-01
PWB Camera Light Calibration
SHEET
1/3
PWB Camera Light Calibration
Perform this working on both heads on the front side and rear side.
[Necessary jigs]
• Calibration plate jig
• Jig positioning pin
• Light Calibration jig
[Procedure]
1 Install the calibration plate jig.
For mounting method of the calibration plate jig, refer to “Install the Calibration Plate Jig [HLGB-10101-01]”.
2 Press the [ORG] button on the operation panel to perform origin position return.
3 Display a PWB Camera Light screen screen.
1. Click the Machine Setup button on the
CALIBRATION screen.
Machine Setup screen is displayed.
2. Click the PWB Camera Light button
on the Light Calibration screen.
PWB Camera Light screen is displayed.
Calibration plate jig
Jig positioning pin
Light Calibration jig

Calibration
HLGB-10301-01
PWB Camera Light Calibration
SHEET
2/3
4 Select jig No. of light calibration jig from the
list box.
5 Move the PWB camera to above the
calibration plate jig.
1. Click the XY button on the PWB
Camera Light screen.
XY Axis screen is displayed.
2. Click the Jog Move button.
3. Jog move the PWB camera to above
the calibration plate jig.
4. Click the Return button to return to
the PWB Camera Light screen.
6 Click the Calibration Start button.
“Put jig under PWB camera” is displayed on the
message screen.