MAN00000772_SI-G200BB_SVCPDFA - 第246页

Calibration HLGB-1031 1-01 Pickup Position Setup SHEET 2/9 2 Press the [ORG] button on the operation p anel to perform origin position return. 3 Display a P ARTS SUPPL Y screen. 1. Click in an order of M/ C SETUP men u …

100%1 / 712
Calibration
HLGB-10311-01
Pickup Position Setup
SHEET
1/9
Pickup Position Setup
Pickup position setup can be performed at three locations on the front cassette table (Z106, Z120,
Z139) and at three locations on the rear cassette table (Z106, Z120, Z135).
Perform pickup position setup for tray specification only on the rear side cassette table (Z101, Z108,
Z117).
[Necessary jigs]
Pickup point Jig
Length reference nozzle jig
Thickness gauge
[Preparation before work]
1 Set the jig.
1. Install the length reference nozzle jig
to the turret No.1.
When installing the nozzle, insert it while
slowly turning.
After inserting the nozzle, check that it is not
drawn out by pulling downward.
2. Set pickup point jig to Z106 on the
cassette table.
There should be no gap between the feed
adjusting jig and the cassette table.
Pickup point Jig
Length reference
nozzle jig
Thickness gauge
Length reference
nozzle jig
Pickup point Jig
Calibration
HLGB-10311-01
Pickup Position Setup
SHEET
2/9
2 Press the [ORG] button on the operation panel to perform origin position return.
3 Display a PARTS SUPPLY screen.
1. Click in an order of M/C SETUP menu
PARTS SUPPLY tab.
Cassette position coordinates are displayed on
left part of the PARTS SUPPLY screen.
4 Display a Front/All Cass. Pos. Teaching by
Tools screen.
1. Click the Teaching button on the Front
Pos. Data to display a drop down
menu.
2. Click the Jigs in the drop down menu.
The Front/All Cass. Pos. Teaching by Tools
screen is displayed.
5 Set the jig.
1. Click the Tool Setup button.
Tool Setup screen is displayed.
Cassette position coordinates
Calibration
HLGB-10311-01
Pickup Position Setup
SHEET
3/9
2. Check jig information (ΔY) attached
on the side of the pickup point jig.
3. Enter value ofΔY written on the side
of the pickup point jig into the ΔY box
on the jig setting screen.
4. Click the Set button.
The value of ΔY is set and the jig setting screen
is closed.
5. Input thickness of “0.03” of thickness
gauge used for H axis position data
teaching.
The value of the spacer thickness becomes
offset value when acquiring H coordinate.