Calibration HLGB-10313-01 Mount Accuracy Calibration SHEET 9/1 1 2. Display OPERA TION SETUP to check that settings are as follows. Motion Mode: Normal Opr . Parts-Out Mode: S top Pre-Pick Mode: OFF Auto Recovery: OFF Pa…

Calibration
HLGB-10313-01
Mount Accuracy Calibration
SHEET
8/11
[Batch recognition calibration]
1 Read machine data of “1005C BatchTransCalibrationFront.PW4.”
To execute the calibration for the rear head, select “1005C BatchTransCalibrationRear.PW4”.
1. Click in an order of AUTO menu
STATUS tab … button.
Select PWB File screen is displayed.
2. Select “
1005C
BatchTransCalibrationFront.PW4
”, and
click the Select button.
In the Supply Position field, enter the supply
unit number on which you placed the cassette.
2 Perform NC reset and then check MOTION
Setup.
1. Click the NC Reset button on the
MOTION Setup (Unit) screen.

Calibration
HLGB-10313-01
Mount Accuracy Calibration
SHEET
9/11
2. Display OPERATION SETUP to check
that settings are as follows.
Motion Mode: Normal Opr.
Parts-Out Mode: Stop
Pre-Pick Mode: OFF
Auto Recovery: OFF
Parts Alternate: OFF
Stop Mode: Cycle Stop
3. Display Motion Setup (Unit) screen to
check that settings are as follows.
Nozzle Escape Detect: Yes
Display result of recognition: No
Unload PWB First: Turned off
3 Press [START] button on the operation
panel and fit parts onto the simple
measuring glass PWB.
Fitting operation is performed for one cycle, and then
the unit stops.
Make sure the wrong pickup or pickup error
does not occur.
4 When fitting is completed without error,
display the accuracy correction screen.
1. Click in an order of M/C SETUP menu
M/C MAINTENANCE tab
Calibration button.
A confirmation window to clear machine data is
displayed.

Calibration
HLGB-10313-01
Mount Accuracy Calibration
SHEET
10/11
2. Click the OK button on the
confirmation window.
The next confirmation window displays “Head at
opposite position will be moved to
noninterference area. Press the [START] button if
you are really OK.”
3. Press the [START] button on the
operation panel.
CALIBRATION screen is displayed.
5 Click the Mount accuracy calibration button.
Mount accuracy calibration screen is displayed.
6 Make sure the message “Global
transcription calibration” is displayed in the
Calibration contents field, and then click the
Start calculation calibration data button.