Calibration HLGB-10314-01 XY A xis Sof tware Limit Setup SHEET 6/1 1 [Rear side sof tware limit checking procedure] 1 Press the [REAR] button on the opera tion panel on the rear side. Operation right moves to the rear si…

100%1 / 712
Calibration
HLGB-10314-01
XY Axis Software Limit Setup
SHEET
5/11
3 Check X coordinate of the software limit
sensor in X axis positive direction.
1. Press the [ORG] button on the
operation panel to perform origin
position return.
2. Click in an order of MANUAL menu
CASS. tab.
Cassette operation screen is displayed.
3. Input “140” into the cassette position
input box and click the Move button.
The head moves to the cassette position “140”.
4. Click in an order of M/C SETUP menu
ORG OFFSET tab XY button.
XY Axis screen is displayed.
5. Click the Jog Move button.
6. Press the right cursor to jog-move Y
axis in positive direction.
When Y axis moves to the software limit
position, alarm is displayed.
7. Press the [RESET] button on the
operation panel to cancel the alarm.
8. Check that the present position of X
axis displayed on the operation screen
of XY axis is same as the value
calculated in the setup procedure 1.
Calibration
HLGB-10314-01
XY Axis Software Limit Setup
SHEET
6/11
[Rear side software limit checking procedure]
1 Press the [REAR] button on the operation
panel on the rear side.
Operation right moves to the rear side.
2 Check X coordinate of the software limit
sensor in X axis positive direction.
1. Press the [ORG] button on the
operation panel to perform origin
position return.
2. Click in an order of MANUAL menu
CASS. tab.
Cassette operation screen is displayed.
3. Input “101” into the cassette position
input box and click the Move button.
The head moves to the cassette position “101”.
4. Click in an order of M/C SETUP menu
ORG OFFSET tab XY button.
XY Axis screen is displayed.
REAR button
Calibration
HLGB-10314-01
XY Axis Software Limit Setup
SHEET
7/11
5. Click the Jog Move button.
6. Press the right cursor to jog-move X
axis in positive direction.
When X axis moves to the software limit
position, alarm is displayed.
7. Press the [RESET] button on the
operation panel to cancel the alarm.
8. Check that the present position of X
axis displayed on the operation screen
of XY axis is same as the value
calculated in the setup procedure 1.
3 Check Y coordinate of the software limit
sensor in Y axis positive direction.
1. Press the [ORG] button on the
operation panel to perform origin
position return.
2. Click in an order of MANUAL menu
CASS. tab.
Cassette operation screen is displayed.
3. Input “101” into the cassette position
input box and click the Move button.
The head moves to the cassette position “101”.
4. Click in an order of M/C SETUP menu
ORG OFFSET tab XY button.
XY Axis screen is displayed.