Calibration HLGB-10315-01 Conv ey or Wi d th A djus tme nt SHEET 1/2 Conveyor Width Adjustment [Procedure] 1 Perform origin position return of conveyor . 1. Click in an order of MAN UAL menu  PWB TRANSPORT tab  C o nv …

100%1 / 712
Calibration
HLGB-10314-01
XY Axis Software Limit Setup
SHEET
11/11
4. Click in an order of M/C SETUP menu
ORG OFFSET tab XY button.
XY Axis screen is displayed.
5. Click the Jog Move button.
6. Press the upper cursor to jog-move Y
axis in positive direction.
When Y axis moves to the software limit
position, alarm is displayed.
7. Press the [RESET] button on the
operation panel to cancel the alarm.
8. Check that the present position of Y
axis displayed on the operation screen
of XY axis is same as the value
calculated in the setup procedure 1.
9. Press the [ORG] button on the
operation panel to perform origin
position return.
Calibration
HLGB-10315-01
Conveyor Width Adjustment
SHEET
1/2
Conveyor Width Adjustment
[Procedure]
1 Perform origin position return of conveyor.
1. Click in an order of MANUAL menu
PWB TRANSPORT tab Conv.
Wid. Adj. button.
Conv. Adj. screen is displayed.
2. Press the [ORG] button on the
operation panel with the Conv. Adj.
screen being displayed.
Conveyor return to origin.
2 Set the conveyor width to 410 mm.
1. Click the Abs. Move button on the
Conv. Adj. screen.
2. Input “410” into the input box of the
Conv. Width Abs. Pos.
3. Press the [START] button on the
operation panel.
Conveyor width is widened to the position of 410
mm.
3 Measure conveyor width on the following six
locations with digital caliper.
Take notes of measured values.
Digital caliper
Conveyor L Middle conveyor Conveyor R
(1) (2) (3) (4) (5) (6)
Calibration
HLGB-10315-01
Conveyor Width Adjustment
SHEET
2/2
4 Set offset value of conveyor on the conveyor
parameter screen.
1. Click in an order of M/C SETUP menu
CONV. PARAM tab.
Conveyor parameter screen is displayed.
2. Enter a difference value between the
value of narrowest conveyor width
measured in the procedure 3 and the
standard value “410.5 mm” into the
CV offset box.
Example: Measured value: 410.1 mm
•••••••••Input value “-0.4”
Measured value: 410.7 mm
•••••••••Input value “0.2”
3. Click the Set button.
Offset value for conveyor width is set.
5 Manually move the conveyor width to 410 mm again, and check that the conveyor width is within
the standard value (410.5 mm) with digital slide calipers in the same procedure as in the
procedures 1 to 3.
If the conveyor width is not within the standard value, repeat the procedures 1 to 4 until the conveyor width falls within
the standard value.