MAN00000772_SI-G200BB_SVCPDFA - 第327页

Adjustment HLGB-10414-01 Phase A djustment for Nozzle SHEET 2/7 2 Move the head to a position by manual operation where working can be easily performed. 1. Click in an order of MAN UAL menu  AXIS MOTION tab  XY button.…

100%1 / 712
Adjustment
HLGB-10414-01
Phase Adjustment for Nozzle
SHEET
1/7
Phase Adjustment for Nozzle
Perform this working on both heads on the front side and rear side.
[Necessary jigs]
A Phase adjusting jig (1)
B Phase adjusting jig (2)
C Pull-out jig
D Torque driver (15[cNm]40[cNm])
[Procedure]
1 Turn off the VACUUM breaker.
Turn OFF the VACUUM breaker before
removing the mechanical valve in order to
prevent suction of contaminant and dust from
the mechanical valve.
1. Loosen the screws (2+T4×8) to
remove the lower cover on the back of
the unit.
2. Turn off the VACUUM breaker on the
power unit part.
Lower cover
VACUUM breaker
A
B
D
C
Adjustment
HLGB-10414-01
Phase Adjustment for Nozzle
SHEET
2/7
2 Move the head to a position by manual
operation where working can be easily
performed.
1. Click in an order of MANUAL menu
AXIS MOTION tab XY button.
XY Axis screen is displayed.
2. Click the Jog Move button in the move
mode.
3. Press the right cursor to jog-move the
head to vicinity of No.120 of head
supply part.
4. Click the Return button to close the
XY Axis screen.
3 Remove the mechanical valve.
1. Loosen CP-3x10 to remove the
mechanical valves for Index 1 and
Index 2.
Mechanical valve
Adjustment
HLGB-10414-01
Phase Adjustment for Nozzle
SHEET
3/7
4 Remove the inner shaft for turret No.1.
1. Click the RT button on the Axis
MOTION screen.
Turret RT Axis screen is displayed.
2. Click the Jog Move button.
3. Press the left and right cursor key to
move the turret No.1 to the front.
Click the Return button to close the Turret RT
Axis screen.
4. Turn the notch on the spring holder to
deep side.
5. Pull the spring holder toward you with
the spring being lowered down to
remove the spring holder.
Be careful to prevent the inner shaft from
falling.
6. Remove the spring.
7. Pull out the inner shaft from lower
side of the head.
5 Press the emergency stop switch to turn off
the servo.
Spring holder
Spring
Spring
Inner shaft