Adjustment HLGB-10417-01 Adjustment of Cassette Float Sensor Height SHEET 3/3 8 Adjust the height of the BS-63T att achment bracket at the position of No.39 on the cassette table. 1. Set the feed adjustin g jig and casse…

Adjustment
HLGB-10417-01
Adjustment of Cassette Float Sensor
Height
SHEET
2/3
5. Check that there’s no gap between the
cassette table and support column
mounting face.
Thickness gauge of t=0.02should not be
inserted between the mounting faces.
3 Pull the bracket for the cassette float sensor
up to the upper end and temporarily tighten.
1. Loosen the cap screws (2-M4) on the
attachment bracket for the cassette
float sensors (left side: BS-63R, right
side: BS-63T) installed in the vertical
frame of the base stand.
2. Pull the bracket up to the upper end
and temporarily fasten.
4 Check that sensitivity level of BS-63R is
MAX.
5 Set the feed adjusting jig to the No.1
position on the cassette table.
There should be no gap between the feed
adjusting jig and the cassette table.
6 Place the cassette float sensor height
adjusting jig on the end of the feed adjusting
jig.
7 Adjust the height of the BS-63R.
1. Adjust the BS-63R attachment bracket
position so that the LED for the
BS-63R lights up at a part of 5 mm on
the cassette float sensor height
adjusting jig, and the LED
extinguishes at a part of 6 mm.
2. Fasten the cap screw to fix the
attachment bracket.
3.
Again, move the cassette float sensor
height adjusting jig back and forth to
check that the LED turns ON/OFF well.
Attachment bracket
Cassette float sensor
Feed adjusting jig
Cassette float sensor
height adjusting jig
Cassette float sensor
height adjusting jig
Attachment bracket
5 mm
6 mm
Optical axis

Adjustment
HLGB-10417-01
Adjustment of Cassette Float Sensor
Height
SHEET
3/3
8 Adjust the height of the BS-63T attachment bracket at the position of No.39 on the cassette table.
1. Set the feed adjusting jig and cassette float sensor height adjusting jig on the position of
No.39 on the cassette table.
There should be no gap between the feed adjusting jig and the cassette table.
2. Adjust the height of the BS-63T attachment bracket in the same procedure as in the
procedure 7.
9 Check that the LED for the BS-63R normally responds at the position of No.20 on the cassette
table.
Check that the LED for the BS-63R lights up at a part of 5 mm on the cassette float sensor height adjusting jig, and the
LED extinguishes at a part of 6 mm.
10 Finally, again, check that the LEDs for the BS-63R and BS-63T normally respond at the positions of
No.1, 20 and 39 on the cassette table.
If the height is respectively adjusted at the positions of No.1, 20 and 39 on the cassette table, response
condition adjusted at the previous position varies. Be sure to check response of the sensor at the 3
locations after adjustment.
11 Remove the jig.
1. Remove the cassette float sensor adjusting jig and feed adjusting jig.
2. Remove the replacing carrier.
12 Also, adjust the cassette float sensors (BS-375T, BS-375R) on the rear side in the same procedure
as the procedures 3 to 11.

Adjustment
HLGB-10418-01
Adjustment of PWB Stopper Sensor
SHEET
1/2
Adjustment of PWB Stopper Sensor
[Procedure]
1 Set PWB on the conveyor.
Any PWB sized to be mountable on this
machine can be allowed.
Mountable PWB:
- Minimum PWB dimension: 50 x 50 mm
- Maximum PWB dimension: 460 x 360 mm
- PWB thickness: 0.5 to 2.6 mm
2 Raise the PWB stopper.
1. Click in an order of MANUAL menu
PWB TRANSPORT tab to open the
PWB TRANSPORT screen.
2. Click the Stopper Up button to raise
the PWB stopper.
3 Adjust gap between PWB end face and
PWB stopper sensor to 2mm.
1. Loosen the fixing screws for PWB
stopper sensor.
2. Adjust the position of the sensor so
that the gap between the PWB and the
PWB stopper sensor.
The gap can be easily adjusted by inserting a
hexagon wrench of 2 mm between the PWB and
the PWB stopper.
3. Tighten the fixing screws for the PWB
stopper sensor.
PWB stopper sensor
2 mm
PWB
PWB stopper
PWB
PWB stopper sensor
Sensor amplifier
Fixing screw