Adjustment HLGB-10419-01 Fixed Camera Pickup Ch eck Sensor Adj ust ment SHEET 4/7 2. Click the Jog Move button. 3. Press the cursor key and m ove the center of the fixed c amera jig nozzle to cross point of the hair lin …

100%1 / 712
Adjustment
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
SHEET
3/7
5 Check that the displayed value on the
sensor amplifier is “3800” or more.
1. Check that the displayed value on the
sensor amplifier is “3800” or more.
When the displayed value is less than 3800,
adjust the sensitivity according to the following
procedures 2. and 3.
2. Loosen the sensor bracket mounting
bolt, and move the sensor bracket up
and down, to left and right to adjust
the fiber sensor mounting position.
3. Loosen the set screw to adjust rotating
direction of the pickup check sensor.
6 Release the emergency stop switch to
return the unit to the origin.
1. Turn the emergency stop switch to
release emergency stop.
2. Click the [ORG] button to return the
system to the original position.
7 Move the head to a position where working
can be easily performed and install the jig
nozzle for fixed camera to the turret No.1.
8 Move the center of the fixed camera jig
nozzle to cross point of the hair lines on the
XY Axis screen by manual operation.
1. Click in an order of MANUAL menu
AXIS MOTION tab XY button.
XY Axis screen is displayed.
Nozzle Jig for
fixed camera
Set screw
Sensor amplifier
Mounting bolt
Sensor
bracket
Fiber sensor
Emergency stop
switch
ORG button
Adjustment
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
SHEET
4/7
2. Click the Jog Move button.
3. Press the cursor key and move the
center of the fixed camera jig nozzle to
cross point of the hair lines on the
PARTS DISPLAY screen.
4. After moving the head, click the
Return button to close the XY Axis
screen.
When performing this operation immediately
after auto calibration, absolute-move the head to
the position described
on#PbPointForFixedCam1 in Calibration.dat
using MANUAL/AXIS MOTION menu to adjust
fine position. More accurate position adjustment
will be possible.
9 Put “Fixed camera parts presence/absence
sensor adjustment jig“ on “Fixed camera
jig base“.
Fixed camera parts presence/absence
sensor adjustment Jig
Adjustment
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
SHEET
5/7
10 Servo off only H-axis.
1. Click in an order of M/C SETUP menu
ORG OFFSET tab Indv. Axis
button.
Indv. Axis Servo screen is displayed.
2. Click the servo OFF button for H axis.
Servo for H axis is turned off.
11 Check whether “Sensor adjusting nozzle
(1) “ is under the “Jig nozzle for fixed
camera“. Fix “Fixed camera parts
presence/absence sensor adjustment
jig“ After check the position of “Sensor
adjusting nozzle (1) “.
Fixed camera parts presence/absence
sensor adjustment Jig
Nozzle Jig for
fixed camera